8.8 Extras/additional adjustments 

In certain applications, advanced settings and an intervention in the transport stream are necessary. In the menu 
item 

Extras,

 settings can be made for these applications. 

 

8.8.1 Func

tion „Password“ 

The menu item 

Password Settings

 allows changes of the access data to the device and with this an increased 

access security.  

 

Click on 

Extras * Password Settings 

 

 

 

 

Important: 

Please  make  sure  to  note  the  serial  number,  as  this  is  required  to  reset  the  password  if  

 

necessary. The serial number is displayed on the Overview window (overview). 

 
If the password is lost or forgotten, we will be happy to help with the general password reset. For this we would 
need the serial number of the device. The serial number can also be found on the label on the outside of the 
device housing. The general password reset can only be done by POLYTRON. For this process we generate a 
new password with which the device can be unlocked again.  
 

Note: 

The password protection is activated ex-works. 

 
After pressing the button 

Password Settings

, the following input menu will be opened. 

 
                                              
 
 
 
 
 
 
 
 
 
 
 
If required, assign a new user name (consisting of letters, numbers or special characters) in the 

Username 

field.  

In the 

New Password 

field, enter the new password with at least 6 digits (consisting of letters, digits or special 

characters in any order). Then enter the new password again in the 

Confirm Password 

field.  

Click 

Change password 

to save the new password. 

 

Note:

  

After changing / saving the new login data, the login data is queried again when the next  

 

 

operation is attempted. 

 

 

 

 

 

Confirmation:  

Password matches 

the specifications 

and is identical 

Summary of Contents for 5552340

Page 1: ...1 PXU 848 IP IP Streamer with multiplexing User manual MADE IN GERMANY 0902481 V1...

Page 2: ...ngle Program Transport Streams ___________________ 16 8 2 6 CI menu_______________________________________________________________ 19 8 2 7 Device NIT _________________________________________________...

Page 3: ...onnection on the device can be used Other devices within touching distance are to be integrated in the equipotential bonding Operation without a protective conductor connection device grounding or equ...

Page 4: ...damage the insulation that serves to isolate the mains voltage Termination Unused coaxial connections should be terminated with 75 Ohm terminating resistors For DC supplied connections DC voltage dec...

Page 5: ...errestrial or cable channels into IP streams The reception mode can be selected individually at each of the eight inputs DVB S S2 DVB T T2 or DVB C Four of the eight channel strips are each provided w...

Page 6: ...3 and J6 The operating states are indicated by external LEDs 6 Mounting The IP Streamer must be installed in a well ventilated room The ambient temperature must not exceed 45 C It must be ensured that...

Page 7: ...T input tuners 1 2 5 and 6 a 12 V DC voltage is applied for LNB supply DVB T and DVB C are connected via the terrestrial input A 12 V supply is optionally available at the terrestrial input tuners 4 a...

Page 8: ...kSym 77 ZDF Vision HH 11954 27500 kSym 107 SAT 1 Pro Sieben HH 12545 22000 kSym 89 RTL World HH 12188 27500 kSym ASTRA Das Erste ZDF SAT 1 RTL Television BR FS S d 3sat ProSieben RTL2 hr fernsehen KiK...

Page 9: ...RTP 5 NDR Niedersachsen 28226 239 1 1 113 10001 RTP 5 MDR Th ringen 28230 239 1 1 114 10001 RTP 5 Eurosport 31200 239 1 1 115 10001 RTP 6 HSE 24 31210 239 1 1 116 10001 RTP 6 EuroNews D 31230 239 1 1...

Page 10: ...browser Chrome Firefox Internet Explorer etc Notes PC notebook and the IP streamer must be in the same network IP address range Cookies must be accepted and JavaScript must be enabled Use current brow...

Page 11: ...very 3 seconds The upper part of the menu shows the device data such as type serial number hardware version and the software versions for CPU IP CI ASI controller und MUX The information about the tot...

Page 12: ...button If the tuner locks on the the data is accepted and the desired transponder Tuner Locked transponder is set is displayed in the upper field Reception conditions DVB S S2 The quality of the inpu...

Page 13: ...is accepted And the desired channel is set If the tuner locks on the transponder Tuner Locked is displayed in the upper field Reception conditions DVB T T2 C The quality of the input signal can be ev...

Page 14: ...5 The network protocol can also be selected separately for each channel strip Factory setting RTP For further information on IP address and port see section 7 1 Input presetting Clicking on Set confir...

Page 15: ...layed On the left side of the window the list of available TV and radio services from the input is shown In the column IN the input slot input tuner of the respective program is displayed In the colum...

Page 16: ...IP addresses ports and network protocols can separately be set for each service program either manually or automatically via the control panels below The network protocol can be selected separately f...

Page 17: ...gnment of the channel numbers to the desired programs click the Save button The configuration will be saved Precondition is that the IP TV sets STBs support M3U lists By clicking on Download M3U List...

Page 18: ...data entries In the case of an error e g double assignment of the IP address the corresponding input fields are highlighted in red as following After correcting and re entering all data they must be s...

Page 19: ...No CAM available appears if the menu item is selected If the CAM module with the corresponding smart card is not recognized no services can be decrypted The settings can be done in advance of the ins...

Page 20: ...possible Network Name Can be defined by the user Country Factory setting Germany changes possible The country code should be the same as the receiver setting TSID New If necessary a new TSID can be as...

Page 21: ...uired the IP Streamer can be restarted Storage of settings or overviews Click on Settings Save Load Settings After selection of Save Load Settings the following window will be opened Save the overview...

Page 22: ...ttings the upload of an existing programming dataset from the PC notebook to IP Streamer PXU 848 IP is possible The data will then be loaded automatically within about 45 60 seconds Select the corresp...

Page 23: ...n window will be opened and a restart of the device occurs This takes approx 50 seconds After the restart the system data is loaded and the window Overview opens automatically 8 4 Network settings Cli...

Page 24: ...a different network address the IP address must be adapted accordingly Example The PC operated in the network has the following settings IP address 192 168 1 068 Network share Host share The IP addre...

Page 25: ...input frequency ASI Sync ASI 188 Clipping Monitoring of the internal transport streams CAM Plugged Confirmation that the CAM module is plugged in CAM Initialized Confirmation that the CAM module is in...

Page 26: ...FPGA green configured ready to operate off error 12 V green 12 V voltage okay off power supply error CI green CAM 1 4 detected and initialized off no CAM detected Status green all tuners locked ready...

Page 27: ...pt the update process and cause the unit to stop responding or require repair Click on Menu Software Update Use Select to find the appropriate folder with the update file select the bin file and open...

Page 28: ...e The serial number can also be found on the label on the outside of the device housing The general password reset can only be done by POLYTRON For this process we generate a new password with which t...

Page 29: ...that are processed by the IP streamer Click Save to apply the changes Note In the factory setting the teletext is switched on 8 8 3 Function MUX Bitrate Settings The menu MUX Bitrate Settings allows t...

Page 30: ...30 9 Application 8x MPTS 128x SPTS...

Page 31: ...0 Roll off 0 35 0 25 0 20 DVB T Modulation QPSK 16QAM 64QAM FFT 2K 8K Bandwidth 7 8 MHz Code rate 1 2 2 3 3 4 5 6 7 8 Guard interval 1 4 1 8 1 16 1 32 DVB T2 Modulation QPSK 16QAM 64QAM 256QAM FFT 1K...

Page 32: ...hme H Q Order department 49 0 70 81 1702 0 Technische Hotline Technical hotline 49 0 70 81 1702 0 Telefax 49 0 70 81 1702 50 Internet http www polytron de Email info polytron de Technische nderungen v...

Reviews: