LAB964R, Issue 4, May 2014

 

 

 

Page 5 

 
 

Physical specification  

 

 

 

 

    

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Net weight 3.25kg 
 
 
 

Installation 

 

3.1 

The following instructions are intended to help prevent hazards. Installation should only be carried out 
by a qualified electrician and competent persons in clean, dry conditions where dust and humidity are 
at minimum levels. 

 
 

Note: we advise installers to fix all mains, switch and sensor wiring (in accordance with the latest 
edition of the Wiring Regulations) prior to fixing the 

CMX

 appliance in position.  

 
3.2 

When accepting delivery of the 

CMX

 appliance, inspect for transit damage. If in doubt, call our 

Customer Service team on 08443 715523. 

 
3.3 

The 

CMX

 appliance can be fitted directly to a ceiling, wall or suitable timber support (if loft mounting). It 

can also be fitted within small ceiling voids and between joists above 400mm spacing. 

 
3.4 

Appropriate screw fixings to suit the support medium will need to be supplied by the installer. The 
support plate is pre-drilled to suit 4 x 4mm (No.8) round/pan-head screws and flat washers. 

 
3.5 

Ensure that there is sufficient space for carrying out any future maintenance on the appliance.  

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Silavent CMX

Page 1: ...ructions must be given to the householder DO NOT SWITCH OFF THE UNIT it is designed to run continuously If the unit is switched off indoor pollutants and moisture levels may increase which could endan...

Page 2: ...tly followed to prevent hazards to life and property both during and after installation and any subsequent servicing or maintenance 10 In dwellings where it is intended to install open flue appliances...

Page 3: ...4 2 Physical specification Page 5 3 Installation Page 5 4 Ducting guidelines Page 6 5 Electrical Page 7 6 Wiring Page 7 7 Remote switch wiring diagrams Page 8 8 External sensor wiring diagrams Page 9...

Page 4: ...t manual OCCUPIED UNOCCUPIED LOW BOOST switch code ANC849A Manual BOOST and UNOCCUPIED selection switches OCCUPIED LOW speed is engaged upon connection of mains supply UNOCCUPIED speed is intended to...

Page 5: ...fixing the CMX appliance in position 3 2 When accepting delivery of the CMX appliance inspect for transit damage If in doubt call our Customer Service team on 08443 715523 3 3 The CMX appliance can be...

Page 6: ...with Approved Document F of The Building Regulations 4 5 When passing through a fire stopping wall or fire compartment wall Domus FireBrake intumescent duct connectors should be used in order to comp...

Page 7: ...0V 50Hz single phase supply only fused at 3 Amps 5 4 A double pole switch having a minimum contact separation of 3mm must be used to provide isolation for the appliance 5 5 Sensor diagrams are shown o...

Page 8: ...4 May 2014 Page 8 7 Remote switch wiring diagrams ANC848A ANC849A ANC850A ANC848A Low Boost functions ANC850A Low Boost Purge functions ANC849A Occupied Unoccupied Low Boost functions BOOST PURGE BOO...

Page 9: ...IMPORTANT CONNECTIONS TO THESE TERMINALS MUST HAVE CLEARLY LABELLED ISOLATORS SITUATED ADJACENT TO THE WIRING CENTRE ANC108A OVERRUN TIMER ELE150R SWITCHED LIVE EXTENSION BOARD ANC802A HUMIDISTAT WITH...

Page 10: ...airflow rate will need to be recorded on the Inspection Checklist and Airflow Measurement Test Sheet A completed copy must accompany these instructions and be handed over to the dwelling s owner upon...

Page 11: ...iated parts and components including any ducting using reasonable skill and care and in accordance with the instructions provided with it unless the original installation maintenance or repair which g...

Page 12: ...Email Polypipe Ventilation Sandall Stones Road Kirk Sandall Industrial Estate Kirk Sandall Doncaster DN3 1QR UK Tel 08443 715523 Fax 08443 715524 International Tel 44 0 1302 348878 International Fax...

Reviews: