UV SANITIZER DISASSEMBLY AND STORAGE

A. First, unplug the UV Sanitizer. Insert the plugs for pool servicing to the pool wall. Disconnect the Water Hoses

from the pool wall. 

B. Slowly unscrew the Vent Screw (23) from the Top Cover (5) to allow the filter system to depressurize.

C. Unlock the Top Cover Retainer (4) by turning counter-clockwise. Remove the Top Cover (5).

D. Loosen the Hose Clamps (26) to remove the Water Hoses (11, 12) and allow water to drain out.

E. Clean and dry all UV Sanitizer parts.

F. Liberally lubricate the O-rings (20, 22) at the Top Cover (5) on the Vent Screw (23) with petroleum jelly, and then

reassemble it along with the Top Cover (5), Vent Screw (23), Top Cover Retainer (4) onto the Main Housing (19). 
Store all parts carefully.

1. Check the hose connections in the UV Sanitizer periodically to make sure there is no leakage of water.

MAINTENANCE

TROUBLE SHOOTING GUIDE

DISCONNECT ELECTRICAL CORD BEFORE TROUBLESHOOTING THE UV SANITIZER

SYMPTOM

PROBLEM

POSSIBLE SOLUTION

1  UV Sanitizer is not cleaning

    pool (water cloudy, green, 

A

 UV Tube failure

A

  Unlock the Top Cover Retainer (4) and check the UV Tubes (7). Replace the UV Tubes if necessary.

2  Water Leakage 

A

  Adjust the Hose Clamp (26). Check O-ring (1) and retighten. Check water hoses for if there is any

A Connection points

holes or cracks. Replace if needed. See page #3.

B

 Vent Screw

B

  Check O-ring (22) for damage. Replace if needed. Lubricate with petroleum jelly.

C

 Top Cover Retainer/ Top Cover

C

  

Check O-ring (20) for damage. Replace if needed. Lubricate with petroleum jelly.

   etc.)

Refer to the UV Tube Replacement Procedures on page #7.

1. UV SANITIZER INSTALLATION: (Refer to Page 3, 4; Fig. 1, 2, 3)

WARNING - 

EXTREMELY IMPORTANT!

• Risk of electrical shock, connect only to a grounding type receptacle protected by a ground fault circuit

interrupter, (GFCI). Contact a qualified electrician if you cannot verify that the receptacle is protected by
a GFCI.

• Receptacle must be at least 10 feet away from pool.
• Do not use an extension cord to connect unit to electric supply; provide a properly located outlet. 
• Do not bury the cord.

NOTE -

 The UV Sanitizer consists of:  UV Sanitizer; Power Adapter; Hardware Bag (Hose Adapters, Hose Clamps); 

and Water Hoses.

     The UV Sanitizer can be used with Skimmer Pump (Fig.1) or RP Pump (Fig. 2) filter system.
A. Remove all parts from the packaging box.
B. Make sure to switch off your swimming pool pump before connecting the UV Sanitizer to your pool.
C. Unscrew the Vent Screw (23) from the Top Cover (5).  Get the Water Hoses (11, 12), and remove four Hose Clamps

(26) from the hardware bag.  Loosen the Hose Clamp Screws (25) and slide the Hose Clamps (26) over one end of
each hose. Lubricate the O-rings (1, 22) on the Return Fitting Elbow (2) and the Vent Screw (23) liberally with
petroleum jelly.

D. Install the Water Hoses (11, 12) on each of the Return Fitting Elbow (2) on the UV Sanitizer. Tighten both of the

Hose Clamps (26). Remove the Water Hose which connects your existing pump outlet to the water return fitting
on the pool wall. Install the Water Hose (IN) (11) on the UV Sanitizer to the the pump outlet and tighten it with
the Hose Clamp (26).  Install the Water Hose (OUT) (12) on the UV Sanitizer to the water return fitting on the pool
wall and tighten it with the Hose Clamp (26).

E. Unscrew the Vent Screw (23) from the Top Cover (5) about 2 turns.  NOTE: VENTING THE SYSTEM IS NECESSARY

FOR AIR TO ESCAPE AS THE UV SANITIZER FILLS WITH WATER.

G. Start the swimming pool pump to allow water pumping into the UV Sanitizer. When the UV Sanitizer is full, water

should be coming out of the groove of the Vent Screw (23).  Hand-tighten the Vent Screw into the Top Cover (5)
until the O-Ring (22) seals around the Vent Screw (23) and no more water is escaping. Check to ensure no
leakage at the Top Cover Retainer (4) and the Return Fitting Elbows (2), tighten them if necessary.

H. Press the Power Switch on the UV Sanitizer to start the sanitizing system for the swimming pool.

F. Connect the pins of the Extension Cord (17) from the UV Sanitizer to the Power Adapter (18). Tighten the screw

nut on the Extension Cord with the Power Adapter. Plug-in the Power Adapter to the power socket.

Summary of Contents for UVS-1012

Page 1: ...ts of God outside the control of Polygroup IN NO EVENT SHALL POLYGROUP THEIR AUTHORIZED AGENTS RELATED ENTITIES OR EMPLOYEES BE LIABLE TO THE BUYER OR ANY OTHER PARTY FOR DIRECT OR CONSEQUENTIAL DAMAGES Some states or countries or others jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Should you...

Page 2: ... Ea 3 1 READ ALL INSTRUCTIONS CAREFULLY and get a thorough understanding of what is required to assemble to your Type of Pool and Filter System 2 Before you begin to assemble the UV Sanitizer identify count and check all parts needed for assembly Refer to the PARTS LIST Page 8 3 It is recommended that you have some PETROLEUM JELLY on hand for lubricating the gaskets 1 Installer shall follow writte...

Page 3: ...e is protected by a GFCI Receptacle must be at least 10 feet away from pool Do not use an extension cord to connect unit to electric supply provide a properly located outlet Do not bury the cord NOTE The UV Sanitizer consists of UV Sanitizer Power Adapter Hardware Bag Hose Adapters Hose Clamps and Water Hoses The UV Sanitizer can be used with Skimmer Pump Fig 1 or RP Pump Fig 2 filter system A Rem...

Page 4: ...emove the UV Tube Socket from the defective UV Tube Remove the defective UV Tube 7 Insert a new UV Tube Plug in the UV Tube Socket to the UV Tube Put back the UV Tube End Cover Tighten the UV Tube End Cover with screws Put back the Bottom Cover Tighten the Bottom Cover with screws Done 1 WARNING To reduce the risk of electric shock the parts should be completely dry before servicing Disconnect fro...

Reviews: