12
USE OF PUMP
IMPORTANT!
This Cartridge Filter Pump is protected by a thermal switch, a safety device that stops the pump from running when it's overheated, to prevent
pump damage and prolong service life. If your pump turns off automatically, it’s likely the pool water temperature is too high or the water flow through the pump is
insufficient for cooling the pump down. Check and correct the water flow, make sure motor rest 15 minutes at least and then restart the pump by pressing the RESET
button of the GFCI Plug, or run the pump at night when the temperature is lower. If pump turns off automatically again, insepct your pump rotor block by dirt.
PUMP MOTOR CARE
1. Check the pump output daily. If water flow reduces, see Symptom 2 of
TROUBLESHOOTING GUIDE (p. 17).
2. Check the Pump, Hoses and Fittings for leaks. If a leak is found, see Symptom 4 of
TROUBLESHOOTING GUIDE.
3. It’s essential to replace any damaged parts as soon as possible. Use only spare parts from approved, reliable dealers, or from
polygroupstore.com
4. Inspect the filter and all filter media regularly to ensure that there’s no build-up of detritus that prevents good filtration. See
FILTER CARTRIDGE USE & CARE
below.
5. Run the Pump for the recommended number of hours daily. If you are unsure of the time frame, please see
Pump Operation Hours
at
support.polygroupstore.com.
PUMP MAINTENANCE
1. To clean the Filter Cartridge
a
:
a. Unplug the Pump from the power outlet.
For the Suction Fitting
2
: seal it with the SF Cap
5
.
For the Return Fitting
6
: remove the RF Diverter
7
, and seal it with
the Service Plug
8
.
b. Vent the Pump by slowly loosening the Vent Screw
e
counterclockwise.
See
SETUP INSTRUCTIONS (9), p.11.
FILTER CARTRIDGE USE & CARE
1. Plug the GFCI Power Cord Set
j
to a properly grounded receptacle at least 15 feet (4.5m) away from the pool.
2. To turn on the Pump, press the RESET button of the GFCI Plug.
3. From inside the pool, check if the water flow from the RF Diverter
7
is correct. It should feel like a solid stream of water
returning to the pool. If not, or if you feel a reduction in flow, clean or replace the Filter Cartridge
a
. For details, see
FILTER CARTRIDGE USE & CARE
below as well as Symptom 2 of
TROUBLESHOOTING GUIDE (p. 17).
4. To turn the Pump off, press the TEST button of the GFCI Plug, and unplug it from the power outlet.
5.
VERY IMPORTANT:
Check and adjust the pH and chlorine levels daily.
FILTER PUMP ALONE WILL NOT PREVENT ALGAE FROM GROWING IN POOL WATER;
THIS CAN ONLY BE DONE BY MAINTAINING PROPER CHLORINE AND pH LEVELS AT
ALL TIMES. For details, see
POOL WATER CARE (p. 13)
.
5
2
8
7
6
Inside Pool Wall
14
12
14
12
IMPORTANT:
Do NOT connect to a timer device!
Press
"RESET"
Button
To Start
Pump
Operation
How to use the GFCI plug
*Do not connect
to a timer device
26
Summary of Contents for RX330
Page 8: ...8 9 6 7 5 27 1 4 8 RETURN FITTING 2 27 1 3 4 10 SUCTION FITTING 26 11 28...
Page 9: ...OWNER S MANUAL 9 12 13 14 20 25 24 25 15 27 17 19 21 16 27 18 23 22...
Page 20: ......
Page 28: ...8 9 6 7 5 27 1 4 8 ACCESORIO DE RETORNO 2 27 1 3 4 10 ACCESORIO DE SUCCI N 26 11 28...
Page 29: ...9 MANUAL DEL USUARIO 12 13 14 20 25 24 25 15 27 17 19 21 16 27 18 23 22...
Page 40: ......