background image

KEY

DESCRIPTION

RX1000

RX1500

RX600

PART #

1
2
3
4
5
6
8
9

10
11
12
13
14

15

16

18
19
20
21
22
24

*

Suction Fitting Base

     Suction Fitting Screen

      Flow Diverter

      Plug

Hose

Hose Clamp

Vent Screw

Vent Screw O-Ring

Seal Top

Base

Canister Gasket

Filter Pump Canister

Nozzle

Motor Assembly

Motor Assembly(UK)

Type D Filter Cartridge

Type A/C Filter Cartridge

Rotor Assembly

Volute Cover

Volute Cover Lock Nut (X-600 & X-1000)

Volute Cover Bolt and Nut Set (X-1500 only)

Filter Pump Port / Fitting O-Ring

102” Hose

For RX Series Filter Pump sold separately

P58PF2820P01

P58PF7780W05
P58PF7790W05

P58PF0620K01
P58150036W01
P58219221W05
P58182201W05

P58182501K01

P58PP1853W05

P58183901W05

P58164800K01

P58PP1840W05

P58185201K01

P58X1500GS00
P58X1500BS00

P583041080PR

P58050506001
P58184501K01

P5800400080A
P58037000K01

P584150004W1

7. To replace the Rotor Assembly  

18

 , remove the Volute Cover  

19

  and pull out the Rotor Assembly  

18 

 from the Stator  

17

 .   Insert new Rotor Assembly  

18

  into

    the Stator  

18 

.

  8. Align the Shaft properly and fasten the Volute cover  

19

  with the Volute Cover Lock Nut  

20

  or with the Volute Cover Bolt and Nut Set  

21

 . 

  9. Attach the Nozzle  

14 

 to the outlet of Motor Assembly. 

10. Slowly insert the motor assembly  

15

  back into the Canister  

13

 , so that the Nozzle  

14 

 is aligned with the outlet port of the Canister  

13 

.

 11. Tighten the Base  

11 

 by turning clockwise, be sure the Gasket  

12 

 is properly in place. To lock the Base  

11

 , apply the latch pin by turning to the right.

      

REPLACEMENT PARTS ORDERING INFORMATION

RX1500

21

19

18

17

RX600/1000   

20

19

18

17

16

17

OWNER’S MANUAL

Winterizing Your Pump and Long-term Storage

After usage, you can easily empty and store away your pump in a safe place. Some pump owners, however, choose to leave their pump up all year round. In cold areas,

where freezing temperatures occur, there can be a risk of ice damage to your pump. We therefore recommend you drain, disassemble, and properly store the pump,

when the temperature drops below 32 degrees Fahrenheit (0 degrees Celsius).

Clean the Pump Water Thoroughly

1. Let the pump cool down for at least 30 minutes before storage. Clean the pump water thoroughly. 

2. Use only damp cloth soaked in mild soap / detergent and water to clean the outer surfaces of the pump. Do not use any kind of chemical or solvent. Always unplug

    the pump and stow the cord during cleaning.

3. Keep out of reach of direct sunlight and chemical substances.

4. Save the original packing box for storage purposes. 

5. Remove the pipes (if applicable) and store in a safe place. Be sure all accessories parts are clean and completely dry before storage. 

6. Bring pump and assessories. indoors and store in a safe and dry area, preferably between 32 degrees Fahrenheit (0 degrees Celsius) and 104 degrees Fahrenheit

    (40 degrees Celsius).

PUMP STORAGE & WINTERIZING

P58PF2820P01

P58PF7800W05
P58PF7790W05

P58PF0620K01
P58125036W01
P58220221W05
P58182201W05

P58182501K01

P58PF1007W05

P58100740W05

P58147800K01

P5810030AW05

P58182601K01

P58X600CGS00
P58X600CBS00

P583041037PR

P58050137001

P58PF1009K01
P58PF1010K01

P58030001K01

P584125002W1

P58PF2820P01

P58PF7780W05
P58PF7790W05

P58PF0620K01
P58150036W01
P58219221W05
P58182201W05

P58182501K01

P58PF1007W05
P58PF1013W05

P58147800K01

P58PF1006W05

P58182601K01

P58X1000GS00

     P58X1000BS00 

P583041080PR

P58050505001

P58PF1009E09
P58PF1010K01

P58037000K01

P584150004W1

Summary of Contents for RX1000-NF

Page 1: ...age or labor are not covered under this Limited Warranty This Warranty will be declared invalid should the Purchaser modify or repair the product themselves or by unauthorized persons use non Polygrou...

Page 2: ...roperly maintain clarity of the pool water at all time Check the pH and chlorine levels periodically and make sure they are within the recommended limits Additional water treatment chemicals might be...

Page 3: ...accessible 44 NOTE The weather may compromise the performance and lifespan of your filter pump If it is exposed to cold direct sunlight or heat it may become unusable so you should protect it from the...

Page 4: ...ol the plug must be easily accessible 44 NOTE The weather may compromise the performance and lifespan of your filter pump If it is exposed to cold direct sunlight or heat it may become unusable so you...

Page 5: ...0 RX1000 RX1500 21 19 18 17 20 19 18 17 9 10 16 12 13 15 14 11 12 8 9 10 16 12 13 15 14 11 12 8 9 10 16 12 13 15 14 11 12 8 RX600 22 22 7A RX1000 22 22 7B RX1500 22 22 7C 5 6 1 1 2 4 3 8 9 OWNER S MAN...

Page 6: ...freely accessible must run on low voltage 12V power Any electric device powered by 220V must be situated more than 2 metres from the edge of the pool Contact the manufacturer regarding any modificatio...

Page 7: ...um or mineral deposits Check pool chemistry for high pH or alkalinity this may cause a calcium or mineral build up 8 A spare stand by Filter Cartridge 16 is an excellent investment It provides a conve...

Page 8: ...Seal Top 10 D Check O ring 12 for damage Replace if needed Tighten the Base 11 2 To depressurize the Filter Pump system vent the filter pump by twisting the Vent Screw 8 counter clockwise 3 Loosen the...

Page 9: ...Winterizing Your Pump and Long term Storage After usage you can easily empty and store away your pump in a safe place Some pump owners however choose to leave their pump up all year round In cold area...

Reviews: