background image

7

5

6

1. Set up the pool by following all instructions that come with the pool. Do not 

    fill water until the Filter Pump is properly installed. Locate the Outlet and 

    Inlet openings on the pool wall.

3. Install the return fitting on the Inlet opening of the pool. 

2. Install the Suction Fitting on the outlet opening of the pool.

4. Remove the Filter Pump        , Hoses        , and Hose Clamps        from

    the package.

SETUP INSTRUCTIONS

WARNING: 

POSITION THIS PRODUCT AWAY FROM THE POOL, SO AS TO PREVENT CHILDREN FROM CLIMBING ON IT AND ACCESSING THE POOL.

Before assembling your product, please take a few minutes to check the contents and become familiar with all the parts.

•  All electrical components must be installed in accordance with standard NFC 15-100.

•  CAUTION: All filters comply with the installation standard NF EN C 15-100, stipulating that any electrical device situated less than 3.5 metres from the pool and 

   which is freely accessible must run on low-voltage 12V power. Any electric device powered by 220V must be situated more than 2 metres from the edge of the pool. 

   Contact the manufacturer regarding any modifications to one or more parts of the filter system.

7

5

6

7

1

3

1

2

Inlet

Outlet

8. Do not plug in the filter pump at this point. Begin to fill water until the water   

    level reaches the fill line.

5. Connect the Hose  

 form the Suction Fitting  

6

  to the Filter Pump 

    Inlet.

6. Connect the Hose  

5

  form the pool Return Fitting to the Filter Pump 

    outlet. 

7. Tighten all Hose Clamps  

6

  to prevent water leakage.

9. Air is now trapped inside the Filter Pump system, which will prevent the 

water from flowing smoothly.  To VENT the system (release the trapped 

air), open the Vent Screw  

 at the top of the pump by turning it 

counter-clockwise.  The water pressure will force out all the trapped air 

inside the Filter Pump system.  Tighten the Vent Screw  

8

  when you see 

water flowing out from the Seal Top  

10

 .

10. Adjust the  Flow Diverter  

3

  to maximize the circulation of the       

      pool water. 

5

6

5

6

10

8

10

8

3

10

11

OWNER’S MANUAL

Summary of Contents for RX1000-NF

Page 1: ...age or labor are not covered under this Limited Warranty This Warranty will be declared invalid should the Purchaser modify or repair the product themselves or by unauthorized persons use non Polygrou...

Page 2: ...roperly maintain clarity of the pool water at all time Check the pH and chlorine levels periodically and make sure they are within the recommended limits Additional water treatment chemicals might be...

Page 3: ...accessible 44 NOTE The weather may compromise the performance and lifespan of your filter pump If it is exposed to cold direct sunlight or heat it may become unusable so you should protect it from the...

Page 4: ...ol the plug must be easily accessible 44 NOTE The weather may compromise the performance and lifespan of your filter pump If it is exposed to cold direct sunlight or heat it may become unusable so you...

Page 5: ...0 RX1000 RX1500 21 19 18 17 20 19 18 17 9 10 16 12 13 15 14 11 12 8 9 10 16 12 13 15 14 11 12 8 9 10 16 12 13 15 14 11 12 8 RX600 22 22 7A RX1000 22 22 7B RX1500 22 22 7C 5 6 1 1 2 4 3 8 9 OWNER S MAN...

Page 6: ...freely accessible must run on low voltage 12V power Any electric device powered by 220V must be situated more than 2 metres from the edge of the pool Contact the manufacturer regarding any modificatio...

Page 7: ...um or mineral deposits Check pool chemistry for high pH or alkalinity this may cause a calcium or mineral build up 8 A spare stand by Filter Cartridge 16 is an excellent investment It provides a conve...

Page 8: ...Seal Top 10 D Check O ring 12 for damage Replace if needed Tighten the Base 11 2 To depressurize the Filter Pump system vent the filter pump by twisting the Vent Screw 8 counter clockwise 3 Loosen the...

Page 9: ...Winterizing Your Pump and Long term Storage After usage you can easily empty and store away your pump in a safe place Some pump owners however choose to leave their pump up all year round In cold area...