OPERATION
-
37-
ADJUSTMENT OF HEATER TEMPERATURE
There are connectors E,D,C,B & A on the primary side of heater transformer.
Connector A is the highest temperature and E is the lowest one.
Adjust accordingly.
NOTE: Do not change wire No.2.
NOTE: Before making this adjustment, make sure 100 volt circuit is maintained at 100-105 VAC, as set by
transformer T2.
Heater Transformer
2
4
Low Temperature
Primary Connector