background image

 

 

2011-04-

6 Ou

opt

The rem
the regul
regulatio
converte
sense lea
voltage d
converte
voltage r

Figure 9

 
The sens
respectiv
The sens
system, d
 

 

Figure 9

 

7 Ou

pro

7.1 St

In case th
output, a
output v
the conv
The trigg
the nomi
long as t

 

26 

tput volt

tion S. 

mote voltage s

lation at the 

on is moved t

er where the 

ads than 3 m 

difference be

er should not

range. Use tw

9.  

se leads must

ve pole, even

se cannot be 

described in 

9. Remote sen

tput ove

otection 

tandard fe

the regulation
a secondary r

oltage level. 

verter output 

ger voltage i

inal voltage. 

the over volta

 

tage sen

sense is used

load. The vo

to a point ou
sense is conn

m is not recom

etween the lo

t be larger tha

wisted sense 

t always be c

n if not used 

used in a par

section 4. 

nse connecti

er voltage

OVP 

eature 

n circuit fails

regulation cir

The circuit a

from externa

s set to 115%

The circuit i

age condition

 

Cop

se, 

d to improve 

oltage 

utside the 

nected. Long

mmended. Th

oad and the 

an the output

wires, 

see 

connected to

externally. 

ralleled 

 

ion. 

s on the 

rcuit limit th

also protects

al voltages. 

% to 120% of

is active as 

n remains. 

pyright 2000-2

ger 
he 

he 

7

A
us
ac
tr
vo
Th
ex
of
11
st
tr

8

Th
an
be

8

Th
co
vo
Th
fr
co

 

F

8

Th
se
is
2.
Th
Fo
co
 

INSTAL
PSC seri

2011

.2 OVP 

o

An independe

sed as over v

ctivated it sh

igged OVP b

oltage. 

he circuit pro

xternal voltag

f the unit. Th
15% to 120%

tandard on al

igger at max

8 Output

he alarm circ

nd trigger wh

elow -10% o

.1 Logic 

his standard 

ollector alarm

oltage, 

see F

he voltage su

rom the conv

ombined with

Figure 10. Ala

.2 Relay 

he alarm has

electable NO

 insulated fro

.5 kVa.c., 

see

he relay is ra

or higher vol

ontact Polyam

LATION M

es AC inpu

option A 

nt circuit usi

voltage prote

ort circuits th

by switching

otects the con

ges as well a

he OVP trigg

% of the nom

ll 5 V master

x. 6.2 V. 

t low vol

cuit monitors

hen the outpu

of nominal ou

signal ala

feature cons

m in referenc

Figure 10

upply to the a

verter output.

h the alarm r

arm pin-out 

output ala

s dry contact 

O, NC functio

om both inpu

e Figure 11.

 

ated 30V 0.5A

ltage/current

mp. 

MANUAL 

uts

 

Pa

ing a SCR th

ection. When

he output. R

g off and on t

onverter from

as regulation 

ger voltage is

minal voltage

r outputs and

tage ala

s the output v
ut voltage be

utput voltage

arm 

sist of an ope
ce to the outp

alarm can be

. It cannot be

relay option. 

and voltages

arm, optio

output with 

on. The relay

ut and outpu

 

A (a.c. & d.c

t relay rating

age 10(14) 

hyristor is 

Reset a 

the input 

m high 

failures 

s set to 

. OVP is 

d will 

rm 

voltage 

ecome 

e.  

en 

put 

e taken 

s. 

on B 

y output 

t  

c.).  

g please 

 

Summary of Contents for PSC100

Page 1: ...w p info p Tel 4 Tel 4 nstalla C DC P PSC10 C100 olyamp com polyamp se 46 85946930 46 85946930 ation M Power 00 PS PSC24 PSC15 m EU DU 00 CA 05 NC Manua r supp SC150 40 50 with T3 Ma U VAT no SE UNS n...

Page 2: ...lid on pecificatio Manua d actual as have been changes in quilateral and maint ccompanyi d within a insulated f sufficien c shock to Caution ock do no ng to quali f conform age directi INSTAL PSC seri...

Page 3: ...s are paralleled on the output 8 5 Multiple loads at the output 9 5 1 Short circuits 9 6 Output voltage sense option S 10 7 Output over voltage protection OVP 10 7 1 Standard feature 10 7 2 OVP option...

Page 4: ...called rectangular characteristic When the current limit is reached which is adjusted to 5 of above mentioned nominal output current this is the maximum current that will continuously flow The output...

Page 5: ...0 e An optiona ovided on 5V r increase the PSC150 and P ed life of the rter temperat rature is lowe oximately do cater for good duce ambient pecifications n of conform nnecting inpu es are not ne plie...

Page 6: ...he potentiometer marked V ADJ on the front panel Clockwise turn increases the output voltage The potentiometer has 15 turns If you have connected units in parallel on the output the procedure of adjus...

Page 7: ...eded with thi alarm a redundant ould be tor alarm to nal relay dry e 10 n N 1 m with two redundancy series diode larm Relay onnected n can be correctly on 4 6 3 pyright 2000 2 or de ub e he on no is y...

Page 8: ...e voltag diode ii Repea desire To achiev converters before the all units th so that the desired LATION M es AC inpu ase the outpu he output vo meter marked it with the low reach the des ntil the outpu...

Page 9: ...ected w can be eet of the fuse t current one branch an hes does al current of ltage will dro ending on th uit whether i oad and the the effects rcuit currents til the fuse is ed voltage di essarily re...

Page 10: ...o vo Th fr co F 8 Th se is 2 Th Fo co INSTAL PSC seri 2011 2 OVP o An independe sed as over v ctivated it sh igged OVP b oltage he circuit pro xternal voltag f the unit Th 15 to 120 tandard on al igge...

Page 11: ...lay can s d d c values gher isol tion E2 to 2 5 kVa c e The emissi be connected NO pair 0 25 m of the remov onnector pin d NC pair 0 25 m of the remov onnector pin m with intern shows Alarm 2500Va c f...

Page 12: ...mag ation tester a with a 10 M and case test shall onl personnel aw azards of th Cop test n tested in ote that ge the Y erformance o minimize or a c between The output t models Optio cannot supply a D...

Page 13: ...ng on test inp input to c ables from th put terminals e See Figure ut terminals t olation tester See Figure 13 e of the isola Vd c Check t does not exce not be applied nds or the Y ed ation tester a w...

Page 14: ...en Contact your Polyamp dealer 11 2 The input fuse blows when the input is connected 1 Change the fuse and switch on the input again If the fuse blows again then the unit is broken 2 Contact your Poly...