background image

LECOLOGICO AS807

39

E

E

N

N

G

G

L

L

I

I

S

S

H

H

The lance 

(F) 

is recommended for thorough

vacuum cleaning of hard-to-reach spots such as
skirting boards and folds in sofas, armchairs,
upholstered furniture and car upholstery. Apply
the radiator brush 

(L) 

to the tip of the lance 

(F)

to clean inside radiator elements and remove
accumulated dust.

Soft brush (G)

The soft brush has soft bristles for dusting deli-
cate surfaces such as picture frames, books,
etc.

Using the tool holder (H) and tool holder
housing (11)

The tool holder may be used to fasten tools onto
the body of the appliance or the handle. 

Installation on the handle: 

Hook one of the

tool holder rings to the handle. Insert the tools
you want to keep handy in the rings (fig.12).

Replacing on the appliance body: 

Slide the

tool holder guide into the groove on the back of
the appliance as shown in figure 12a, proceed-
ing to anchor the tools as described above. You
may perform the same operation to replace the
universal brush 

(C) 

with the telescopic tube 

(A)

attached to it (fig.12b).

Using the flexo joint (I)

This special joint allows you to reach hard-to-
reach spots without bending down. Insert the
Flexo joint between the hose and the telescopic
tube, holding the notch on the front part of the
handle. To change its inclination, rotate the cur-
sor 

(Y) 

(fig.11) by a half turn. The joint that

allows you to alter the working angle of the tube
will then appear (fig.11). Put the joint back in its
original position when you have finished, and
cover it with the cursor to lock it in place.

Mini turbo brush (N)

The mini turbo brush is particularly recommend-
ed for cleaning sofas and armchairs, car uphol-
stery, fabric-covered walls, etc.
It easily removes dust, dandruff and textile
residues. It is useful for preventing allergies, as
the mechanical action of the roller with bristles
vacuums up animal hair. 
Periodically clean the mini turbo brush as fol-

lows:
• Slacken the screws on the base of the tool

(fig.21).

• Separate the two parts that make up the

brush (fig.22).

• Vac up dirt inside the brush with the tube with

no tool on it (fig.23).

• Close the brush again, performing these

operations in reverse order (fig.24).

Turbo Brush (O) (Optional)

The turbo brush is designed for perfect cleaning
of carpets with a maximum pile length up to 15
mm. The rotating brush effortlessly picks up
threads, hair, animal hair and other particles
which are normally particularly difficult to vacu-
um up. The turbo brush may successfully be
used on hard surfaces too.

A

A

U

U

T

T

O

O

M

M

A

A

T

T

I

I

C

C

 

 

C

C

A

A

B

B

L

L

E

E

 

 

W

W

I

I

N

N

D

D

E

E

R

R

Before putting the vacuum cleaner away, rewind
the power cable by pressing the button (

2

), as

shown in fig.9, being careful to accompany it
during winding.

G

G

E

E

N

N

E

E

R

R

A

A

L

L

 

 

M

M

A

A

I

I

N

N

T

T

E

E

N

N

A

A

N

N

C

C

E

E

Always make sure the appliance is unplugged
before performing maintenance work of any
kind.

C

C

L

L

E

E

A

A

N

N

I

I

N

N

G

G

 

 

T

T

H

H

E

E

 

 

W

W

A

A

T

T

E

E

R

R

 

 

F

F

I

I

L

L

T

T

E

E

R

R

A

A

S

S

S

S

E

E

M

M

B

B

L

L

Y

Y

 

 

(

(

1

1

6

6

)

)

:

:

Pull the nozzle 

(17c) 

until it comes off the fil-

ter cage. Separate the body of the cage

(17a) 

from the filter cover 

(17)

.

Remove the sponge filter 

(17b) 

from the

cage. If the filter is damaged, replace it.
Rinse all components under running water.
Let the sponge filter dry before putting it
back into the appliance. 

Reassemble the filter assembly, repeating
the operations in the reverse order.

Note: 

Make sure that the filter nozzle 

(17c)

is correctly positioned, checking that the
arrow on the nozzle is aligned with the notch
on the bottom of the cage 

(17a) 

(fig.15).

If the filter needs replacing, always use an
original Polti filter, available by mail order
from the Technical Service Centre.

A cleaning brush 

(Z) 

is supplied for easy

LECOLOGICO AS807 M0S08537 1O09 8 LINGUE:Layout 1

30/09/2008

14.39

Pagina 39

Summary of Contents for LECOLOGICO AS807

Page 1: ......

Page 2: ...9 B Z E H F G C C1 L D1 D A A1 4 17 15 12 6 5 3 14 1 2 8 13 18 11 19 P1 P M 17 W 17b 17a 17c 6 16 O N Lecologico AS807 M0S08537 Edizione 1O09 Fig 12b B1 I 22 21 20 23 24 25...

Page 3: ...2 Fig 3 Fig 4 Fig 5 Fig 8 Fig 11 Fig 7 Fig 6 Fig 12a Fig 13 Fig 1 Fig 14 Fig 15 Fig 16 Fig 17 Fig 9 Fig 10 Fig 18 Fig 19 Fig 20 Fig 21 7 9 9a 10 Fig 22 Fig 23 Fig 24 C L D 4 1 15 Fig 12 Fig 12b Fig 1...

Page 4: ...irt preventing all contact with dust and avoiding dispersal of dust back into the air What is the HEPA filter Lecologico has a special extra powerful washable HEPA filter previously used only in profe...

Page 5: ...eplace the power supply cable please refer to the nearest Polti autho rised service centre since the use of a spe cial tool is necessary Never touch the appliance with wet hands or feet with the cable...

Page 6: ...rived from any use of Lecologico which is not in conformity with the instruc tions contained in this booklet A AT TT TE EN NT TI IO ON N Directive 2002 96 EC Waste Electrical and Electronic Equipment...

Page 7: ...tton is pressed the power of the motor will decrease and the light indicator will go out To restore the appliance to the pause posi tion hold down button 20 Note so that the remote control operates in...

Page 8: ...ic tube A The tube is about 60 cm long when closed 1 m when extended to its greatest length To increase or decrease length press the catch positioned as shown in fig 6 and extend or reduce length as d...

Page 9: ...is useful for preventing allergies as the mechanical action of the roller with bristles vacuums up animal hair Periodically clean the mini turbo brush as fol lows Slacken the screws on the base of th...

Page 10: ...C CO ON NT TR RO OL L B BA AT TT TE ER RY Y THE BATTERY IS NOT SUPPLIED WITH THE PRODUCT In order to work the remote control handle needs to be powered by a 12V type MN21 bat tery The duration of the...

Page 11: ...NOTE...

Reviews: