use before doing any maintenance or cleaning.
• Every so often clean the inside of the supply tube (
L
)
letting clean hot water run through it.
• Regularly check the disk filter (
D
), the gasket (
E
) and
the tube gasket (
M
). Replace only with original spare
parts if there are signs of wear or deterioration.
• Periodically check that the holes in the disk filter (
D
)
are not blocked. Clean it with a pin if necessary.
• Do not wash any coffee maker part in the dishwash-
er.
• Do not use acids or solvents to clean the exterior of
the appliance, just a damp cloth, making sure that
the water does not wet the electrical parts of the appli-
ance.
•
Never rinse the boiler under the tap and never
immerse it in water.
AROMA 850 - 800
ENGLISH
T
T
R
R
O
O
U
U
B
B
L
L
E
E
S
S
H
H
O
O
O
O
T
T
I
I
N
N
G
G
Problem
Cause
Solution
No coffee is released No water in the boiler
Fill the boiler with fresh water
The coffee takes a
long time to be
released
The coffee used is not the right type
The disk filter is blocked.
The coffee has been pressed.
Scale presence into the boiler.
Use ground coffee for Mocha coffee maker
Clean the disk filter as described in the “General
maintenance advice” paragraph.
Do not press the ground coffee.
Remove the scale from the lower vessel
Coffee leaks from the
edges of the boiler.
The disk filter is blocked
The gasket is burned or torn
The coffee maker has not been started
correctly.
Clean the disk filter as described in the “General
maintenance advice” paragraph.
Replace the gasket.
Start the coffee maker correctly.
Summary of Contents for AROMA 850
Page 1: ... ...