17
Description
of
jumper
settings
and
characteristics
The PCB can be set-up in a number of different configurations that are selected using the
appropriate Links.
LEDS
When this jumper is ON , the leds are activated.
AND 1 + 2
This configuration can be useful when tall grass and small animals are
present .
The function can also be programmed through remote control, by
entering a positive c 12V on the terminal marked AND on
the terminal board
BEAM OFF 1
The first beam at the bottom can be excluded, while the remaining
beams continue to function .
The function can also be programmed through remote control, by
entering a positive c 12V on the terminal marked BEAM on
the terminal board
BEAM OFF 1 + 2
The first two beams at the bottom can be excluded, while the
remaining beams continue to function
The function can also be programmed through remote control, by
entering a negative command + 12V on the terminal marked BEAM
on the terminal board
RND DLY ON
Each time the alarm is triggered with a random delay that varies
between 0 and 1 seconds
.
This function is used to confuse and deceive any intruder who
wishes to identify the sensor system.
RND DLY OFF
Alarm command output is generated in real time.
TEST P. SET
During the alignment stage, the bridge must be set in ON
position in order to block the transmission sequence so that it
will not generate signals that can disturb the alignment value
readings.
On completion of the single beam alignment operation, the bridge
should return to the normal OFF function condition.
SINC ON :
WIRE Function programmed in wire synchronism (always
maintain in this position).