background image

 

Politec S.r.l. | Installation manual NAT SENSOR – Ver. 1.10.1 

12 

 

 

 
 

 

 

Example 4

 

 "Back to back" installation 

 

 

N.B.:

 

INSTALL THE TWO SENSORS AT LEAST AT 20cm OF DISTANCE ONE FROM OTHER.

 

 

 

Example 3

 

 "Double" 
installation  

 

 

N.B.:

  

INSTALL 

THE TWO 
SENSORS AT 
LEAST AT 15m 
OF DISTANCE 
ONE FROM 
OTHER.

 

 
 

Summary of Contents for NAT SENSOR

Page 1: ...DUAL TECHNOLOGY SENSOR PIR Microwave Outdoor use INSTALLATION MANUAL ...

Page 2: ... 8 5 ADDITIONAL FEATURES Pag 9 OPEN FIELD FUNCTION Pag 9 EXPOSED AREA FUNCTION Pag 9 IR ANTI MASK FUNCTION Pag 9 MICROWAVE ANTI MASK FUNCTION Pag 9 SECURITY FUNCTION Pag 10 6 DESCRIPTION OF NOT SETTABLE FUNCTION Pag 10 PET IMMUNITY SYSTEM Pag 10 SELF DIAGNOSIS SYSTEM Pag 10 AUTO THERMINAL SYSTEM Pag 10 AUTO ENVIRONMENTAL SYSTEM Pag 10 7 APPLICATION Pag 11 8 PIR LIMITER Pag 13 MOUNTING Pag 15 9 TEC...

Page 3: ...IR range adjustable from 0 to 12m MW range adjustable from 0 to 12m Function and output ANTI MASKING for infrared and microwave RF immunity up to 2Ghz Pet Immunity Small size 135mm x 33mm x 40mm Processing digital signals of PIR and MW Temperature Autocompensation Environmental Autocompensation EXPOSED AREA function Operativity Self scanning of PIR technology Operativity Self scanning of MW techno...

Page 4: ...in case of detection MW IR 6 TAMPER BUTTONS anti removal and anti tear If they get open give the opening of N C 7 DIP SWITCHES System configuration 8 TRIMMER MW rotating in clockwise increases the range sensibility of MW 9 TRIMMER IR rotating in clockwise increases the range sensibility of IR 10 RED LED ALARM lit up when there is a general alarm if enabled 11 YELLOW LED PIR lit up when there is a ...

Page 5: ...LL MOUNTING 1 Insert the shielded cable alarm in the fixing plate 2 Fix the plate at wall 3 Drill hole in the rubber nut and slide inside the cable 4 Screw the base on the plate 5 Fix the NAT motherboard on the support base and connect wires 6 After the wiring and operation test close NAT sure that the seals and the O rings are present and not damaged to ensure the integrity of the product 1 2 3 4...

Page 6: ...le through the mounting plate 3 fix the plate to the fastening bracket angle 4 Drill hole in the rubber nut and slide inside the cable 5 Screw the base on the plate 6 Fix the NAT motherboard on the support base and connect wires 7 After the wiring and operation test close 7 NAT sure that the seals and the O rings are present and not damaged to ensure the integrity of the product 1 2 3 4 5 6 7 ...

Page 7: ...DE VIEW VIEW FROM ABOVE NB the system can also detect the areas underlying the sensor Nat adjusting the range sensitivity of the two technologies see below NB the detecting area can change of some meters depending on the installation height of sensor and surrounding environment ...

Page 8: ...umber 4 for the functionality of the LEDs detection 1 2 3 4 ON NB power on for the duration of about 30 seconds if the DIP4 of the LEDs is activated you will see an alternate flashing of these to stabilize the system Term of flashes you can proceed with the following settings PIR RANGE SENSITIVITY 1 12m REGULATION TRIMMER Adjust the PIR range through the trimmer implementing with crossing test Sub...

Page 9: ...parameters avoiding false alarms 1 2 3 4 ON IR ANTI MASK FUNCTION Turn the dipswitch number 2 for the functionality ANTI MASK Activating this function when an object is placed in front of the sensor to blind it and make it ineffective an active infrared system checks for the presence of these in 3 seconds and gives an output signal through dedicated The anti mask microwave verification of the pres...

Page 10: ... and cats perform function tests SELF DIAGNOSIS SYSTEM The system will periodically check every 50sec about the functionality of the microwave and PIR system In case of Malfunction of one of the two detection equipment this is signaled by the flashing of the LED dedicated GREEN and ORANGE for MW for IR steadily In this condition the system excludes the operation of the technology is not working an...

Page 11: ... the bracket to L and thanks to the new system of AUTO ENVIRONMENTAL is able to reduce to zero the possibility of false alarms The installation MUST be carried out at height between 2 and 3m by adjusting the range and sensitivity of the two technologies MW IR Example 3 Wide detection area installation Example 1 Curtain for windows or doors ...

Page 12: ... NAT SENSOR Ver 1 10 1 12 Example 4 Back to back installation N B INSTALL THE TWO SENSORS AT LEAST AT 20cm OF DISTANCE ONE FROM OTHER Example 3 Double installation N B INSTALL THE TWO SENSORS AT LEAST AT 15m OF DISTANCE ONE FROM OTHER ...

Page 13: ... none interest that can generate more or less important reflections and false detections depending on the type of material present In order to obtain a more precise and safe area of detection it is possible to apply the PIR LIMITER supplied which limits the angle of view of the sensor In this way the sensor detects only interested area LEFT SIDE SENSOR LIMITED ...

Page 14: ...Politec S r l Installation manual NAT SENSOR Ver 1 10 1 14 RIGHT SIDE SENSOR LIMITED ...

Page 15: ...allation manual NAT SENSOR Ver 1 10 1 15 MOUNTING 1 INSERT THE PIR LIMITER INTO THE DEDICATED SIDE TO HIDE THE DESIRED HALF 1 PUSH THE LIMITER DOWN TO THE BOTTOM 2 YOU CAN REMOVE THE DEVICE BY HANDLE WITH THE SCREWDRIVER ...

Page 16: ... 24 125Ghz Angle IR coverage 80 vertical 6 horizontal Angle MW coverage 80 vertical 30 horizontal Power supply 10 16 Vdc Absorption on alarm 42mA Absorption standby 40mA Alarm Output N C Tamper Output N C Max range detection IR Open collector Stand by input INPUT Operating Temperature 20 65 C Dimensions 135mm x 33mm x 40mm Weight 150gr Mounting brackets TOTAL WARRANTY 2 YEARS ...