2  BEFORE YOU BEGIN 

Thank you for purchasing a Polimaster Personal Combined Radiation Detector/ Dosimeter 

РМ

1703

МО

-

1. Before operating this unit, please review this guide thoroughly and retain it for future reference.  
The Personal Combined Radiation Detector/Dosimeter is designed to detect, search, and locate gamma-
emitting  radioactive  sources.  The  detector  is  easily  handled  requiring  only  understanding  of  the  basic 
parameters and settings for proper operation. 
The device is intended for everyday or emergency use by firefighters, military, police, etc. It is designed 
for use in any area where radiation dose and dose rate are required to be measured, where exceeding the 
default  dose  and  dose  rate  values  requires  an  alarm.  In  addition,  the  device  provides  accumulated 
information about the accumulated dose and system analysis of the gathered dosimetric information. 

3  PRECAUTIONS 

1.

 

Keep the instrument at least 4 inches from radio emitting sources, such as cell phones, to avoid 
false positives. 

2.

 

Avoid severe mechanical shocks and submerging the device into water. 

4  GENERAL DESCRIPTION

 

The 

РМ

1703

МО

-1 belongs to Polimaster’s new generation of highly sensitive, small and power-saving 

personal gamma combined radiation detectors/dosimeters. When ON the detector continuously monitors 
the environment for radiation and alerts the user with a visual, audio and/or vibrating alarm if a radiation 
source is detected or a radiation threshold is exceeded.

 

All operations history is stored in the device’s permanent memory, protecting the data even when the 
battery  is  removed.  The  stored  data  can  also  be  transferred  from  the 

РМ

1703

МО

-1  to  a  personal 

computer via its infrared interface. 
The instrument is recommended for detecting and locating radiation sources in both indoor and outdoor 
environments. 

This  device  complies  with  Part  15  of  the  FCC  Rules.   Operation  is  subject  to  the  following  two 
conditions:  (1)  This  device  may  not  cause  harmful  interference,  and  (2)  this  device  must  accept  any 
interference received, including interference that may cause undesired operation

 

4.1  Display and Control Buttons 

The instrument is equipped with two control buttons located on its top panel: 

 

MODE 

button  —  (switching  on  the  instrument;  switching  between  operation  modes;  background 

level calibration; changing the device parameters in setup mode) 

 

LIGHT

 button — (switching on the backlight; enabling IR communications with a PC; changing the 

parameters in setup mode.) 
 

Summary of Contents for PM1703MO-1

Page 1: ..._________________________________________________________________________________________ 2002 2007 Polimaster Inc and its licensors All rights reserved info polimaster us www polimaster us Personal Combined Radiation Detector Dosimeter PM1703MO 1 OPERATION MANUAL ...

Page 2: ......

Page 3: ...larm Threshold Error Bookmark not defined 5 OPERATION ERROR BOOKMARK NOT DEFINED 5 1 Turning the Unit ON OFF Error Bookmark not defined 5 2 Going through self tests and background calibration Error Bookmark not defined 5 3 Operation Modes Error Bookmark not defined 5 3 1 Search Mode Error Bookmark not defined 5 3 2 DER Dose Rate Measurement Mode Error Bookmark not defined 5 3 3 DE Dose Indication ...

Page 4: ...enabled in your particular Personal Combined Radiation Detector Dosimeter Enabled features are marked by a checked box Detector serial number ________________________ Features and operation modes On off Search mode indication µR h Measurement mode indication µSv h Measurement mode indication µR h Dose mode indication µR Auto calibration Possibility to adjust DER thresholds for other search and mea...

Page 5: ...ves 2 Avoid severe mechanical shocks and submerging the device into water 4 GENERAL DESCRIPTION The РМ1703МО 1 belongs to Polimaster s new generation of highly sensitive small and power saving personal gamma combined radiation detectors dosimeters When ON the detector continuously monitors the environment for radiation and alerts the user with a visual audio and or vibrating alarm if a radiation s...

Page 6: ...ration alarm is enabled Blinking h symbol indicates that there has been an alarm actuation and information about it hasn t been uploaded to a computer Blinking S symbol indicates that the search mode is currently on Critical battery discharge displayed when the battery voltage drops below 1 15 V An analog bar in the lower area of the LCD display indicates the time left until self tests or backgrou...

Reviews: