Test Report
The Test Report is a window with a scrolling menu that by default shows the Resolution Test
results. These results will be useful as a double-check that resolution tests “pass” after mag
and focus adjustments are made to solve color registration problems. Since the Magnification
(Mag) changes with focus adjustment, the Analysis window panel containing Mag results is
just below the Test Report.
Right and Left Resolution Test Report
Vertical and Horizontal (RGB) Results: Figure 5-11 shows 12 results (6 for the left and 6 for
the right) that are all within the spec of > .70
Color Registration Report
If you use the Test Report window scroll bar and scroll down you will see the raw test results
from the motion test. These are the same results as shown on the main scanner test panel.
The results with derived information are reported, again, in the Analysis Window.
Test Constraints
Test limits (specifications) are shown in this area for reference purposes.
Analysis
The Motion Analysis report provides information on the data gathered and the corrective
actions to take after running a Motion and Color Registration test. An experienced user will be
able to analyze the results and decide whether the problems found are caused by mechanical
factors, optical factors or, a combination of the two.
Peak (R-B) Misalignment result - 0.63 pixels which is within the spec of 1.1 pixel or, less.
This means that there is a red to blue color shift of 0.63 pixels somewhere in the image.
Note:
The specification limit for this part of the test is listed at the bottom left of the test
panel under TEST constraints as Peak Misregistration.
You can see the 0.63 pixel peak graphically on the color misalignment graphs. Notice that the
peak appears at line # 900 for the “left side” and is the highest one (with respect to the 0.0
point) and with it’s peak just below the -0.6 point. This is the highest peak when considering
both left side and right side misalignment graphs.
Figure 5-12 shows the left and right side of the chevron pattern which is used to measure the
peak shown on the graph. Notice the parallel lines drawn on the target image. This two areas
mark the points where measurements are taken to calculate the graphical and numerical
data.
Summary of Contents for SprintScan SS35
Page 9: ...Slide Scanner Repair Manual Scanner Overview 9 1 Scanner Overview...
Page 31: ...Slide Scanner Repair Manual FunctionalDescription 31 2 Functional Description...
Page 50: ...50 Slide Scanner Repair Manual Calibration and Adjustments 3 Calibration and Adjustments...
Page 72: ...72 Slide Scanner Repair Manual Parts Replacement 4 Parts Replacement...
Page 96: ...96 SlideScannerRepairManual Diagnostics and Troubleshooting 5 Diagnostics and Troubleshooting...
Page 157: ...157 Slide Scanner Repair Manual System Diagrams 6 System Diagrams...
Page 159: ...159 Slide Scanner Repair Manual System Diagrams Power Supply Specification Sheet 1 of 4...
Page 160: ...160 Slide Scanner Repair Manual System Diagrams Power Supply Specification Sheet 2 of 4...
Page 161: ...161 Slide Scanner Repair Manual System Diagrams Power Supply Specification Sheet 3 of 4...
Page 162: ...162 Slide Scanner Repair Manual System Diagrams Power Supply Specification Sheet 4 of 4...
Page 163: ...163 Slide Scanner Repair Manual System Diagrams AC Inverter PC Board...
Page 164: ...164 Slide Scanner Repair Manual System Diagrams Image Sensor CCD PC Board Sheet 1 of 3...
Page 165: ...165 Slide Scanner Repair Manual System Diagrams Image Sensor CCD PC Board Sheet 2 of 3...
Page 166: ...166 Slide Scanner Repair Manual System Diagrams Image Sensor CCD PC Board Sheet 3 of 3...
Page 184: ...Slide Scanner Repair Manual Appendix 184 Appendix...