A. Feeding Systems
Install the chemical pump and erosion feed systems as shown in
one of the figures on page 8. If your model differs from the pre-
viously mentioned systems, see the installation manual that was
provided with it for the appropriate installation methods.
Note: The controller may have to be set for the particular feeder
system used. See the appendix on page 24.
B. Site Assessment and Controller Installation
Before installing the controller, it is important to do a site assess-
ment and consider where and how you will mount the controller.
The controller should be mounted on a wall or other surface
within eight feet of the feeder, at least ten feet away from the
edge of the water, in close proximity to the time clock and within
six feet of the GFCI power source.
Once you determine the best site, obtain all necessary mounting
screws or anchors (no mounting screws are provided with the
controller). Securely mount the controller on a wall or panel.
C. Sensor Bypass Assembly
Locate the sensor bypass assembly within eight feet of the con-
troller, and mount it using the brackets provided. The sensor
bypass (flowcell) must be plumbed so the pressure difference
between the inlet and outlet is sufficient to ensure flow through
the bypass. It is also desirable to have filtered water pass over
the sensors to minimize cleaning. One method to accomplish
this is to plumb the inlet to the bypass assembly after the filter
(see A in the diagrams on page 8) and plumb the output of the
bypass assembly after the heater (see B) using the saddle
clamps provided.
Mounting Brackets
Compression
Fittings - Sensors
Compact Ball Valves
Ball Valve (Sample Port)
Clear Tees
Check/Flow
Indicator
Sensor Bypass
Assembly