B. Peristaltic Pump is Overfeeding Sanitizer or pH
If you are using the controller with a peristaltic pump, which
feeds slowly, it is better to have a very long feed cycle in order to
provide adequate sanitizer or pH control.
1. Timed Feed Mode = ORP and pH Switch #10 are OFF
2. Feed Cycle in Minutes =
ORP Switch #8 is ON
pH Switch #7 is ON
3. Pool Mode = ORP Switch #7 is OFF
Spa Mode = ORP Switch #7 is ON
4. Choose your desired feed and cycle delay times from the fol-
lowing options.
Recommended Settings
ORP SWITCHES
Feed Cycle
Switch Switch
Delay Cycle
Switch Switch
#3
#4
#5
#6
12 Minutes
OFF
ON
5 Minutes
OFF
OFF
pH SWITCHES
Feed Cycle
Switch Switch
Delay Cycle
Switch Switch
#3
#4
#5
#6
8 Minutes
ON
ON
5 Minutes
OFF
OFF
Optional Settings
ORP SWITCHES
Pool Mode (#7 OFF)
Spa Mode (#7 ON)
Feed Cycle
Switch Switch
Feed Cycle
Switch Switch
#3
#4
#3
#4
12 Minutes
OFF
ON
2 Minutes
OFF
ON
16 Minutes
OFF
OFF
4 Minutes
OFF
OFF
24 Minutes
ON
ON
6 Minutes
ON
ON
32 Minutes
ON
OFF
8 Minutes
ON
OFF
Delay Cycle
Switch Switch
Delay Cycle
Switch Switch
#5
#6
#5
#6
2 Minutes
OFF
ON
1 Minutes
ON
ON
5 Minutes
OFF
OFF
2 Minutes
OFF
ON
10 Minutes
ON
OFF
5 Minutes
OFF
OFF
20 Minutes
ON
ON
10 Minutes
ON
OFF
26