IX. Troubleshooting
PROBLEM
POSSIBLE CAUSE
SOLUTION
SANITIZER LEVEL
Set knob set too low
Adjust knob clockwise until the
TOO LOW
proper sanitizer level is reached and
stabilized
pH level too low (less than 7.2) Check pH level with a test kit
and adjust as required
Chemical feeder empty
Refill chemical feeder
Controller malfunction
Replace controller module
Sensor failure
Replace sensor
SANITIZER LEVEL Sensor dirty
Clean according to the mainte-
TOO HIGH
nance instructions
Set knob set too high
Test the sanitizer with a test kit and ad-
just the ORP knob counterclockwise
until the proper sanitizer level is reached
pH too high (above 7.8)
Check pH level with a test kit and
adjust as necessary
pH LEVEL
Set knob set too low
Adjust pH set knob
TOO LOW
pH calibrate knob
Adjust pH calibrate knob
improperly adjusted
Chemical feed rate too high
Lower feed rate
Chemical feeder empty
Refill chemical feeder
(if using base)
Controller malfunction
Replace controller module
Sensor failure
Replace sensor
pH LEVEL
Sensor dirty
Clean according to the mainte-
TOO HIGH
nance instructions
pH sensor calibration
Adjust pH sensor calibration
improperly adjusted
pH set knob set too high
Adjust knob counterclockwise
Chemical feeder empty
Refill chemical feeder
(if using acid)
Feed pump malfunction
Repair feeder pump
Chemical feed rate too low
Increase feed rate
RED pH ALERT
pH level is below 7.0 or
Manually adjust pH in the pool
LIGHT ON
above 8.2
DISPLAY LIGHTS
No power supply
Check circuit breaker
OFF
FEEDER DOES
Bad fuse
Replace fuse
NOT OPERATE
19
Summary of Contents for Watermatic C-660
Page 31: ...TL 429 1 00 ...