DIAGNOSTIC CODES
COMPONENT
CONDITION
SPN
FMI
EPS MODELS ONLY
Data Erratic,
Intermittent Or
Incorrect
84
2
Abnormal Rate Of
Change
84
10
Received Network
Data In Error
84
19
System Power
Data Valid But Above
Normal Operational
Range - Most Severe
Level
168
0
Voltage Above
Normal, Or Shorted To
High Source
168
3
Voltage Below
Normal, Or Shorted To
Low Source
168
4
Engine Speed
Data Valid But Above
Normal Operational
Range - Most Severe
Level
190
0
Data Erratic,
Intermittent Or
Incorrect
190
2
Received Network
Data In Error
190
19
ECU Memory
Bad Intelligent Device
Or Component
628
12
Out Of Calibration
628
13
Calibration
Out Of Calibration
630
13
Steering Over Current
Shut Down
Current Above Normal
Or Grounded Circuit
520221
6
Steering Excessive
Current Error
Current Above Normal
Or Grounded Circuit
520222
6
Steering Torque
Partial Failure
Condition Exists
520223
31
Steering Torque Full
Failure
Condition Exists
520224
31
55
Downloaded from
Summary of Contents for Sportsman XP 1000 S 2020
Page 3: ...2020 Owner s Manual Scrambler XP 1000 S Downloaded from ManualsNet com search engine...
Page 6: ...4 WELCOME Downloaded from ManualsNet com search engine...
Page 8: ...6 Downloaded from ManualsNet com search engine...
Page 12: ...10 Downloaded from ManualsNet com search engine...
Page 76: ...74 Downloaded from ManualsNet com search engine...
Page 88: ...86 Downloaded from ManualsNet com search engine...
Page 132: ...130 Downloaded from ManualsNet com search engine...
Page 134: ...132 Downloaded from ManualsNet com search engine...
Page 148: ...146 Downloaded from ManualsNet com search engine...
Page 153: ...Downloaded from ManualsNet com search engine...