MAINTENANCE
Battery
Battery Charging
The following battery charging instructions apply only to the installa-
tion of a sealed battery. Read all instructions before proceeding with the
installation of this battery.
The sealed battery is already filled with electrolyte and has been sealed
and
fully charged
at the factory.
Never
pry the sealing strip off or add
any other fluid to this battery.
A sealed battery must always be maintained with a full charge. Since the
battery is sealed and the sealing strip cannot be removed, you must use a
voltmeter or multimeter to measure DC voltage.
WARNING!
An overheated battery may explode, causing severe injury or
death. Always watch charging times carefully. Stop charging if the battery
becomes very warm to the touch. Allow it to cool before resuming charging.
For a refresh charge, follow all instructions carefully.
1. The battery should be disconnected from a load or charger for at
least two hours before checking voltage. Check the battery voltage
with a voltmeter or multimeter. A fully charged battery will register
12.8 V or higher.
2. If the voltage is less than 12.8 volts, recharge the battery at 1.2 amps
or less until battery voltage is 12.8 or greater.
3. When using an automatic charger, refer to the charger manufac-
turer's instructions for recharging. When using a constant current
charger, use the guidelines on the next page for recharging.
Summary of Contents for RANGER XP 900
Page 1: ...Owner s Manual for Maintenance and Safety RANGER RZR XP 900 RZR XP 4 900 TM TM ...
Page 140: ...138 MAINTENANCE LOG DATE MILES KM OR HOURS TECHNICIAN SERVICE PERFORMED COMMENTS ...
Page 141: ...139 MAINTENANCE LOG DATE MILES KM OR HOURS TECHNICIAN SERVICE PERFORMED COMMENTS ...
Page 146: ...The text is printed on 100 recycled with 40 post consumer waste PCW ...