MAINTENANCE
2.21
2004 Four Stroke PWC Service Manual
Bilge Siphon System
1. Clean bilge siphon pickup screens whenever debris
are present.
2. Inspect the .040
″
hole in fitting elbow. It must be
clear to prevent siphoning of water into bilge.
3. Inspect all tie straps to be sure they are tight and in
position.
Bilge Drain Plugs
1. Inspect bilge plug for cracks or damage from
over-tightening.
2. Periodically inspect sealing O-ring and replace if
worn or damaged. Inspect drain plug, gasket,
keeper strap and tightness of screws.
3. Inspect bilge drain plug mounting bolts for proper
torque. Torque mounting bolts to 8 -- 10 in.lbs.
View From
Inside Hull
Screen
To pump fitting
.040
″
hole must
be clear to prevent
siphoning water
into bilge
Bilge Siphon
Plug
O-Ring
Keeper
Strap
Gasket
Bilge Plug
Assembly