Precautions to eliminate the risk
5
10 cm mini
Entaille
du pilier
10 cm mini
Entaille
du pilier
STOP
Cellules photoélectriques
STOP
50 cm
mini
50 cm
mini
12 cm
min.
5 mm
max.
12 cm
min.
5 mm
max.
Fotokomórki
Ścięcie
słupka
ZONE 1
Risk of hit and crushing
Solution:
Obstacle detection system
inside the photocell drive.
Solution:
Obstacle detection
system inside
the drive.
Solution:
If there is a dangerous zone for feet
between the lower part of the gate
leaves and the substrate, leave the
distance at least 12 cm or at most
5 mm between the lower part
of the leaves and the substrate.
Solution:
Obstacle detection system inside the drive.
If there is a risk of user confinement in the
zone between the gate leaves and fixed
elements in the vicinity, leave a minimum
distance of 50 cm between the leaves and
the fixed elements.
Solution:
If there is a cutting zone in the
system:
- leave a minimum distance of
10cm between the leaf and the
post / wall
- cut down the post corner without
its construction weakening.
ZONE 3
Risk of hit
ZONE 4
Risk of confinement and crushing
ZONE 5
Ryzyko obrażeń stóp
ZONE 2
Risk of hand crushing and cutting
10 cm as
min.
Post
bevel
50 cm
as
min.
12 cm
min.
5 mm
max
Photocells
7
EN
- Assembly and service manual for EASY WAY202
EN