4
UK
Telephone Helpline
: 0845 146 2887 (United Kingdom)
Troubleshooting
Technical Specifications
Fault
Probable Cause
Action
The appliance is
not working
The appliance is not switched
on
Check the appliance is plugged in correctly and
switched on
Plug and lead are damaged
Call POLAR agent or qualified technician
Fuse in the plug has blown
Replace the plug fuse
Power supply
Check power supply
Internal wiring fault
Call POLAR agent or qualified technician
Ambient temperature below
10°C
Move appliance to a warmer position
Water supply
Check water supply is on and supply hoses are
not blocked
Appliance is noisy
or works
intermittently
Power fluctuations
Turn off the ice maker and restart after 3 minutes
Compressor runs
but no ice is made
Refrigerant leak or block in the
refrigerant system
Call POLAR agent or qualified technician
Bin is full
Empty bin
Ice cubes not fully
formed
Blocked nozzle
Clean nozzle jets
First ice making cycle
Use ice from second cycle
Ice melted
Do not leave ice in bin for extended periods
Spray bar dislodged/misaligned Reattach spray bar
Condensor Blocked
Clean Condensor
Not producing
enough ice
Ambient temperature too high
Relocate appliance to a suitable position
Water pressure too low
Check water inlet hose/inlet hose filter for
blockages
Condensor Blocked
Clean Condensor
Water comes
through curtain
Spray bar dislodged/misaligned Reattach spray bar
Model
Voltage
Power Current
Ambient
Range
Ice
Making
Capacity
Refrigerant
Dimensions
h x w x d mm
Weight
(kg)
GL193
230V 50Hz 260W
1.8A
16C-32C 22kg/hour
R290a
43.5g
637 x 380 x 520
33
Summary of Contents for GL193
Page 40: ...GL193_ML_A5_v1 ...