background image

4

Telephone Helpline

: 1300225960

Troubleshooting

If your POLAR appliance develops a fault, please check the following table before making a call to the Helpline or your POLAR dealer.

Technical Specifications

Electrical Wiring


The plug is to be connected to a suitable mains socket. 
POLAR appliances are wired as follows:

 Live wire (coloured brown) to terminal marked L

 Neutral wire (coloured blue) to terminal marked N

 Earth wire (coloured green/yellow) to terminal marked E 

All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.

Fault

Probable Cause

Action

The appliance is not working

The unit is not switched on

Check the unit is plugged in correctly and switched on

Plug and lead are damaged

Call POLAR agent or qualified Technician

Fuse in the plug has blown

Replace the fuse

Power supply

Check power supply

Internal wiring fault

Call POLAR agent or qualified Technician

The appliance turns on, but the 
temperature is too high/low

Too much ice on the evaporator

Defrost the appliance

Condenser blocked with dust

Clean condenser with hose attachement of vacuum

Doors are not shut properly

Check doors are shut and seals are not damaged

Appliance is located near a heat source or air flow to 
the condenser is being interrupted

Move the refrigerator to a more suitable location

Ambient temperature is too high

Increase ventilation or move appliance to a cooler position

Unsuitable foodstuffs are being stored in the 
appliance

Remove any excessive hot foodstuffs or blockages to the fan

Appliance is overloaded

Reduce the amount of food stored in the appliance

The appliance is leaking water

The appliance is not properly levelled

Adjust the screw feet to level the appliance (if applicable)

The discharge outlet is blocked

Clear the discharge outlet 

Movement of water to the drain is obstructed 

Clear the floor of the appliance (if applicable)

The water container is damaged

Call POLAR agent or qualified Technician

The drip tray is overflowing

Empty the drip tray (if applicable)

The appliance is unusually loud

The safety band has not been removed

Remove the safety band

Loose nut/screw

Check and tighten all nuts and screws

The appliance has not been installed in a level or 
stable position

Check installation position and change if necessary

Model

Voltage

Power

Current

Temperature

Range

Capacity

(litres)

Refrigerant

Dimensions

H x W x D (mm)

Weight 

(kg)

DL893-A

220-240V 50Hz

380

2.3A

-2°C to 10°C

600

R134a 300g

2010 x 680 x 850

145

DL894-A

220-240V 50Hz

600

2.8A

-15°C to -22°C

600

R404a 360g

2010 x 680 x 850

148

DL895-A

220-240V 50Hz

700

3.3A

-2°C to 10°C

1200

R134a 320g

2010 x 1340 x 850

195

DL896-A

220-240V 50Hz

700

3.3A

-15°C to -22°C

1200

R404a 450g

2010 x 1340 x 850

198

DL897-A

220-240V 50Hz

700

3.3A

-15°C to -22°C

1200

R404a 450g

2010 x 1340 x 850

198

DL898-A

220-240V 50Hz

700

3.3A

-2°C to 10°C

1200

R134a 320g

2010 x 1340 x 850

195

DL899-A

220-240V 50Hz

380

2.3A

-2°C to 10°C

600

R134a 300g

2010 x 680 x 850

145

CK480-A

220-240V 50Hz

600

2.8A

-15°C to -22°C

600

R404a 360g

2010 x 680 x 850

148

Summary of Contents for DL893-A

Page 1: ...Model DL893 A DL894 A DL895 A DL896 A DL897 A DL898 A DL899 A CK480 A Cabinet Refrigerators Freezers Instruction manual ...

Page 2: ...White Freezer Introduction Please take a few moments to carefully read through this manual Correct maintenance and operation of this machine will provide the best possible performance from your POLAR product Pack Contents The following is included POLAR prides itself on quality and service ensuring that at the time of packaging the contents are supplied fully functional and free of damage Should y...

Page 3: ...within the appliance is displayed Control Panel To See the Setpoint Push and immediately relese the SET key the display will show the Setpoint value Changing the Setpoint 1 Push the SET key for more than 2 seconds to change the Setpoint value 2 The value of the set point will be displayed and the COMPRESSOR LED starts blinking 3 To change the Set value push the UP and DOWN buttons within 10 second...

Page 4: ...ive Scourers or scrubbing pads etc Use Chlorinated or acidic detergents Allow anything e g food dirt cleaning chemicals to remain on the surface for longer than necessary clean them off right away Allow the surface to remain wet Do Clean often Use soft Cloths or plastic Scourers Rub with the grain of the metal rather than across it Use detergents and polish designed for cleaning Stainless Steel En...

Page 5: ...erature is too high Increase ventilation or move appliance to a cooler position Unsuitable foodstuffs are being stored in the appliance Remove any excessive hot foodstuffs or blockages to the fan Appliance is overloaded Reduce the amount of food stored in the appliance The appliance is leaking water The appliance is not properly levelled Adjust the screw feet to level the appliance if applicable T...

Page 6: ...environment the product must be disposed of in an approved and environmentally safe recycling process For further information on how to dispose of this product correctly contact the product supplier or the local authority responsible for waste disposal in your area POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international...

Page 7: ...k AS NZ 3820 Essential Safety Requirements for Low Voltage Electrical Equipment Standards EN 55014 1 2006 EN 55014 2 1997 A1 EN 61000 3 2 2006 EN 61000 3 3 1995 A1 A2 EN 61000 3 11 2000 EN 55015 2006 EN 61547 1995 A1 AS NZS 60335 2 89 2002 A1 2003 A2 2005 A3 2007 with AS NZS 60335 1 2002 A1 2004 A2 2007 A3 2007 Producer Name POLAR Producer Address 15 Badgally Road Campbelltown NSW 2560 Date 24 03 ...

Page 8: ...DL893 A_DL899 A_A4_v6 ...

Reviews: