background image

Technical Specifications

Electrical Wiring

The plug is to be connected to a suitable mains socket. 
This appliance is wired as follows:

Live wire (coloured brown) to terminal marked L

Neutral wire (coloured blue) to terminal marked N

Earth wire (coloured green/yellow) to terminal marked E

This appliance must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any 
emergency disconnection being required they must be readily accessible.

Compliance

The WEEE logo on this product or its documentation indicates that the product must not be 
disposed of as household waste. To help prevent possible harm to human health and/or the 
environment, the product must be disposed of in an approved and environmentally safe 
recycling process. For further information on how to dispose of this product correctly, 
contact the product supplier, or the local authority responsible for waste disposal in your 
area. 
POLAR parts have undergone strict product testing in order to comply with regulatory standards and 
specifications set by international, independent, and federal authorities. 
POLAR products have been approved to carry the following symbol: 

Model

Voltage

Power

Current

Temperature

Range

Capacity

(litres)

Refrigerant

Dimensions

H x W x D (mm)

Weight 

(Kg)

CD080-A

220-240V 50Hz 

150

1.0A

-2°C to 8°C

150

R134a (75g)

850x600x600

44

CD081-A

220-240V 50Hz 

150

1.0A

-10°C to -25°C

140

R134a (75g)

850x600x600

44.5

CD082-A

220-240V 50Hz

185

1.5A

-2°C to 8°C

400

R134a (170g)

1850x600x600

69

CD083-A

220-240V 50Hz

210

2A

-10°C to -25°C

365

R134a (185g)

1850x600x600

71

CD084-A

220-240V 50Hz

185

1.5

-2°C to 8°C

600

R134a (210g)

1890x777x695

90

CD085-A

220-240V 50Hz

350

3.5

-10°C to -25°C

600

R134a (290g)

1890x777x695

94

CD610-A

220-240V 50Hz 

150

1.0A

-2°C to 8°C

150

R134a (75g)

850x600x600

44

CD611-A

220-240V 50Hz 

150

1.0A

-10°C to -25°C

140

R134a (75g)

850x600x600

44.5

CD612-A

220-240V 50Hz

185

1.5A

-2°C to 8°C

400

R134a (170g)

1850x600x600

69

CD613-A

220-240V 50Hz

210

2A

-10°C to -25°C

365

R134a (185g)

1850x600x600

71

CD614-A

220-240V 50Hz

185

1.5

-2°C to 8°C

600

R134a (210g)

1890x777x695

90

CD615-A

220-240V 50Hz

350

3.5

-10°C to -25°C

600

R134a (290g)

1890x777x695

94

CD086-A

220-240V 50Hz

150

1.0A

-2°C to 8°C

150

R134a (75g)

850x600x600

47

CD087-A

220-240V 50Hz

185

1.5A

-2°C to 8°C

400

R134a (170g)

1850x600x600

72

CD088-A

220-240V 50Hz

185

1.5A

-2°C to 8°C

600

R134a (290g)

1890x777x695

93

Summary of Contents for CD080-A

Page 1: ...600 400 150 litre series Refrigerators Freezers Instruction manual Models CD080 A CD081 A CD082 A CD083 A CD084 A CD085 A CD610 A CD611 A CD612 A CD613 A CD614 A CD615 A CD086 A CD087 A CD088 A ...

Page 2: ... the appliance Always switch off and disconnect the power supply to the unit before cleaning Keep all packaging away from children Dispose of the packaging in accordance with the regulations of local authorities If the power cord is damaged it must be replaced by a POLAR agent or a recommended qualified technician in order to avoid a hazard This appliance is not intended for use by persons includi...

Page 3: ...le is a heat source Operation Control Panel The control panel is located on the front of the appliance Turn On 1 Close the door of the appliance 2 Connect the appliance to a mains power supply 3 Set the temperature to the desired setting 0 Off 1 Cool to 7 Cold Storing Food To get the best results from your POLAR appliance follow these instructions Only store foodstuffs in the appliance when it has...

Page 4: ...e harmful residues Clean the door seal with water only Always wipe dry after cleaning Do not allow water used in cleaning to run through the drain hole into the evaporation pan A POLAR agent or qualified technician must carry out repairs if required Cleaning the Condenser Periodically cleaning the condenser can extend the life of the appliance POLAR recommend that a POLAR agent or qualified techni...

Page 5: ...r a heat source or air flow to the condenser is being interrupted Move the refrigerator to a more suitable location Ambient temperature is too high Increase ventilation or move appliance to a cooler position Unsuitable foodstuffs are being stored in the appliance Remove any excessive hot foodstuffs or blockages to the fan Appliance is overloaded Reduce the amount of food stored in the appliance Th...

Page 6: ...et by international independent and federal authorities POLAR products have been approved to carry the following symbol Model Voltage Power Current Temperature Range Capacity litres Refrigerant Dimensions H x W x D mm Weight Kg CD080 A 220 240V 50Hz 150 1 0A 2 C to 8 C 150 R134a 75g 850x600x600 44 CD081 A 220 240V 50Hz 150 1 0A 10 C to 25 C 140 R134a 75g 850x600x600 44 5 CD082 A 220 240V 50Hz 185 ...

Page 7: ...any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of POLAR Every effort is made to ensure all details are correct at the time of going to press however POLAR reserve the right to change specifications without notice ...

Page 8: ...86 A CD087 A CD088 A CD080 A CD081 A CD610 A CD611 A CD612 A CD613 A CD614 A CD615 A Legislation C Tick AS NZ 3820 Essential Safety Requirements for Low Voltage Electrical Equipment Standards AS NZS CISPR 14 1 2010 AS NZS 60335 2 89 2010 Producer Name POLAR Producer Address 15 Badgally Road Campbelltown NSW 2560 Date 13 11 12 Signature Full Name Richard Cromwell Position Marketing Director ...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...CD610 A CD615 A_CD080 A CD088 A_v5 ...

Reviews: