(System indicate)
Setting target torque
Apply torque
Apply torque
Current torque value
(Peak hold)
Released
Flashing
Buzzer
Buzzer
Green LED
Reached 90% of target torque
Red LED
Approaching target torque
Reached 90% of target torque
Reached target torque
START
PEAK HOLD MODE OPERATION
((((((((
))))))))
((((((( )))))))
((…((… …))…)) ((…((… …)) …))
*Note 1
*Note 2
*Note 3
Note:
1. If
is appeared, that means this
wrench has ever been applied more than 110%
of torque of the spec.
2. When 90% of the target torque is reached, the green
LED will begin to flash and the alarm tone will beep
intermittently.
3. When 99.5% of the target torque has been reached,
the alarm will change to a steady tone and the green
LED will stop flashing and stay on. The red LED will also
illuminate.
MAINTENANCE AND STORAGE
BATTERY MAINTENANCE
■
When the wrench is not going to be used for an
extended period of time, remove the battery.
■
Keep a spare battery on hand when going on a
long trip or to cold areas.
■
Sweat, oil and water can prevent a battery’s
terminal from making electrical contact.
To avoid this, wipe both terminals before loading a
battery.
■
Dispose of batteries in a designated disposal
area. Do not throw batteries into a fire.
Caution:
1. Over-torquing (110% of Max. torque range)
could cause breakage or lose of accuracy.
2. Do not shake violently or drop wrench.
3. Do not use this wrench as a hammer.
4. Do not leave this wrench in any place
exposed to excessive heat, humidity, or
direct sunlight.
5. Do not use this apparatus in water (it is not
waterproof).
6. If the wrench gets wet, wipe it with a dry
towel as soon as possible. The salt in
seawater can be especially damaging.
7. Do not use organic solvents, such as
alcohol or paint thinner when cleaning
the wrench.
8. Keep this wrench away from magnets.
9. Do not expose this wrench to dust or sand
as this could cause serious damage.
10. Do not apply excessive force to the LCD
panel.
11. Apply torque slowly and grasp the center
of the handle. Do not apply load to the
end of the handle.
12. When checking the accuracy or calibration,
please use the bit head packed inside the
blow mold case.
Attention!
One-year periodic recalibration is necessary to maintain
accuracy. Please contact your local dealer for calibrations.
All manuals and user guides at all-guides.com