![PNI GreenHouse SC1800B User Manual Download Page 25](http://html1.mh-extra.com/html/pni/greenhouse-sc1800b/greenhouse-sc1800b_user-manual_1569954025.webp)
25
User manual
En
gli
sh
13
The maximum
charging current
from the Utility
20A (default)
30A (maximum current)
14
Battery Type
AGM (default)
Flooded
GEL
LEAD
Lithium Ion
Lithium Ion
If “User-Defined” is selected, the battery
charging voltage and the minimum DC cut-
off voltage level can be set in programs 17, 18
and 19.
17
Bulk charging
voltage
(C.V voltage)
24V model default settings: 28.2V
If “User-Defined” is selected in program 14,
this program can be set. The range that can be
set is between 24.0V and 29.2V for 24Vdc.
Each click increases the value by 0.1 V