Output source
priority selection
If the battery voltage drops
to the level set in program
20, the inverter will switch to
bypass mode, consumers will
be powered only from the
public power grid, and the
solar source will charge the
battery.
The public energy network
will be the priority source
of power for consumers.
The solar source and the
battery will supply energy
to the consumers only if the
energy from the public grid
is not available.
02
AC input voltage
range
If selected, the AC input
voltage range will be
between 90-280VAC.
If selected, the AC input
voltage range will be
between 170-280VAC.
If selected, the AC input
voltage range will be
according to VDE4105
(184VAC-253VAC)
If you use a generator as
the power source, select the
generator mode.
03
Output voltage
Set the output voltage range
(220VAC-240VAC)
04
Output frequency