PMI SB5100 Owner'S Manual Download Page 2

01-999-2534

Page 2

CAUTION: the use of anode devices, chemical additives 
or cooler cleaner treatments in this cooler will void the 
warranty. 

INTRODUCTION

Your Shop Blaster evaporative air cooler was thoroughly tested 
and inspected before leaving the factory. This manual is your guide 
to economical, trouble free comfort cooling over the years with 
reasonable care and regular maintenance. Failure to follow these 
instructions may damage your cooler, impair its operation, and/or 
void the warranty. 

Read it carefully.

 

 

PREPARATION

Unpacking the unit
Remove the pad frame by lifting up and pulling outwards.  The float 
kit bag is located in the cooler bottom pan.  Remove the float kit 
bag from the cabinet.  Float kit contains the following items: 

1. Float valve assembly
2. Float bracket
3. Garden hose adapter
4. Overflow stand pipe
5. Drain Bushing Assembly

SET UP FOR USE

The Shop Blaster evaporative cooler may be filled manually with 
the fill door or automatically with the float valve and garden hose 
adapter.

To Install float valve and hose adapter.  Attach the float valve to the 
cabinet as shown in figure 2.  The garden hose adapter attaches to 
the brass inlet fitting on the float valve (

See figure 2

). 

NOTE:

 Verify 

that the hose washers are correctly in place before use.

Next install the overflow stand pipe and drain bushing. Attach the 
stand pipe, drain bushing, and washer in the hole in the drain pan 
in the order shown in 

figure 3

NOTE:

 Verify that the washer is 

correctly in place before use.

 

 

Water connection and float adjustment

Move cooler to desired location (must be a level area for proper 
operation of the cooler).

1. Connect water supply using a commercial grade water hose (not 

supplied with cooler, obtained separately) to the adapter on the 
float valve and turn water on. 

CAUTION:

 water inlet pressure 

should be limited to a maximum of 65 PSI to avoid rupturing the 
water hose. If pressure exceeds this valve, an inline pressure 
regulator should be installed (obtainable from a local plumbing or 
hardware store).

2. Check that all connections are tight by visually inspecting hose, 

float valve, etc. for leakage.

3. Set float valve for a water depth of 2.5". The float is adjusted by 

lightly bending the float rod.

4. Do not insert garden hose into manual fill door; water may harm 

the pump and void the warranty.

Figure 1

Figure 3

Figure 2

Summary of Contents for SB5100

Page 1: ...e receptacle is GFCI protected consult with a qualified electrician This cooler is equipped with a power cord having an equipment grounding conductor and grounding plug Do NOT attempt to defeat this s...

Page 2: ...e to the cabinet as shown in figure 2 The garden hose adapter attaches to the brass inlet fitting on the float valve See figure 2 NOTE Verify that the hose washers are correctly in place before use Ne...

Page 3: ...an overloaded condition and may damage the fan motor The motor and pump have an internal automatic thermal overload switch that will shut the motor and or the pump off if it overheats The motor and o...

Page 4: ...cy longer life and appearance every two months during operation the cooler should be inspected and cleaned Drain water from the unit every 8 10 hours of operation to minimize scaling build up Note Do...

Page 5: ...th a garden hose water may harm motor and pump Motors damaged by water are NOT covered under warranty All foreign materials scale salt deposits lime etc can and should be removed from bottom pan and o...

Page 6: ...lity paint Do not use asphalt type cooler undercoat material in water reservoir Undercoat will break free clogging the pump and water distributor LUBRICATION Motor Bearings Some motors used in Shop Bl...

Page 7: ...eas where mineral content of the water is high or the air is dusty deposits may build up in the cooler pads restricting airflow Clean or replace pads as follows 1 Disconnect power from unit 2 Remove p...

Page 8: ...01 999 2534 Page 8 WIRING DIAGRAM...

Page 9: ...itch 5 Replace belt Inadequate air delivery 1 Excessive belt tension 2 Blower wheel loose on motor shaft 3 Pads clogged 1 Adjust belt tension 2 Tighten wheel set screw 3 Replace pads Noisy operation 1...

Page 10: ...Drawer Slides not shown 05 008 0004 31 Motor Sheave 05 003 0032 1 10 9 17 2 3 4 22 23 24 25 26 31 18 27 BLOWER ASSEMBLY 8 16 15 14 13 12 11 19 20 21 5 7 6 SB5100 Replacement Parts List Item Replaceme...

Page 11: ...om state to state Evaporative Cooler Limited Warranty Phoenix Manufacturing Inc Phoenix Arizona extiende esta garant a limitada al comprador original de este enfriador evaporativo Lo que esta garant a...