background image

Bluetooth. Older recorders employed only the rs-232 cable, while newer Eagle 120 
recorders may have Bluetooth installed as an option. 
  
Once the recorder is powered and the PDA is communicating with the recorder, tap the 
PMIScan icon to reach the Main Menu, consisting of 3 commands: LDU, Comm, and 
Files. 
 

4.8.1 LDU 

This mode allows the user to scroll though a number of screens showing real-time display 
of the measurements that have been enabled: voltage, current, power, phase angle, power 
factor, displacement power factor, and harmonics are possible. The “1 Chan” display 
option shows the measurements on fewer screens than the “4 Chan” option, but both 
sequences show the same information. 

•  

Tap More to scroll through the measurements. 

•  

Tap Next to view other channels. 

 

4.8.2 Comm 

This mode allows the user to perform 6 functions, most importantly Download 
and Initialize: 
1) “Download” identifies the recorder in the heading, allows editing of the 
Identification, and leads to a download. 

•  

Tap Done and OK to initiate the download. See “Downloading Data” 

below. 
2) “Identify” lists information about the individual recorder. 
3) “Date/Time” allows the user to synchronize the recorder with the PDA. 

•  

Tap Set Time to change the Date/Time of the PDA. 

10 4 USING THE Eagle 120 RECORDER 
4) “Initialize” allows the user to set parameters and choose options from a 
 of screens similar to those in ProVision. By default, “Recorder Settings” 
shows the recommended or usual quantities. 

•  

Tap Edit to change the settings. 

•  

Tap Previous or Next to scroll through the numbered screens. 

•  

Tap Done and OK to accept the defaults or the user-selected settings. 

5) “Retrieve Set” uploads the prior group of settings. 
6)

 

“Done” leads back to the Main Menu and accepts the chosen settings. 

 
 

4.8.3 Downloading Data 

When the Technician wishes to collect data from the recorders in the field, the 
PDA serves as a storage medium to convey the data to the office PC. Depending 
on what records are enabled, the memory of the PDA holds downloads 
from several recorders. 
Connect the PDA to the recorder via Bluetooth.  To implement the download: 

•  

Tap Comm, Download, and OK to initiate the transfer. 

Depending on the size of the file, the process could take several minutes. 
The download is complete when the Main Menu appears. Back at the office, 
the PDA may be connected to the PC through the HotSync docking cradle: 

•  

Connect the cradle to the PC according to the instructions for the Palm. 

Summary of Contents for Eagle 120

Page 1: ...Eagle 120 Recorder User s Manual Power Monitors Inc June 6 2006...

Page 2: ...n the established Voltage Recorder line the Eagle 120 Recorder provides a voltage measurement processing and reporting system with a proven performance history In summary the Eagle 120 Recorder Voltag...

Page 3: ...nvenience receptacle is not connected to earth ground Do not plug devices which require an earth ground into the convenience receptacle if this grounding scheme has been defeated The Eagle 120 is not...

Page 4: ...ountdown After the countdown the Eagle 120 Recorder starts recording Later after the desired data is recorded the data from the Eagle 120 Recorder is downloaded into ProVision ProVision is then used t...

Page 5: ...ed data it is downloaded into ProVision or a Palm PDA The Eagle 120 Recorder may be downloaded in the field by connecting the USB cable into a laptop see PC Communications with the eagle 120 Recorder...

Page 6: ...gle 120 Recorder The green LED lights up steadily in this mode to indicate that it is in communications mode and ready for communications In ProVision the recorder serial number will appear within 2 m...

Page 7: ...Date Time allows the user to synchronize the recorder with the PDA Tap Set Time to change the Date Time of the PDA 10 4 USING THE Eagle 120 RECORDER 4 Initialize allows the user to set parameters and...