POLYURETHANE
MACHINERY
CORPORATION
PHDX-2 SERVICE MANUAL
6. INSTALLATION
Figure 14: Component Identification - Misc
CAUTION!
Ensure that the emergency stop is not engaged.
4.
Three Phase Proportioner Only:
Check the Electric Motor to ensure rotation is
clockwise when viewing the end of the Electric Motor. A counter clockwise rotation
indicates two of the incoming power leads need to be reversed.
CAUTION!
Ensure Main Power Switch is OFF and in-
coming power is locked OFF before reversing power
leads.
Recheck rotation before proceeding with Installation.
5. Fill the Lube Reservoir with PMC Pump Lube or suitable diluents. It is not necessary
to prime the system.
REVISION 1.1
25