POLYURETHANE
MACHINERY
CORPORATION
PHDX-2 SERVICE MANUAL
4. TECHNICAL SPECIFICATIONS
4
TECHNICAL SPECIFICATIONS
4.1
ELECTRICAL
PHDX-2, Single Phase, 208-240V
Pressure
Heater Size
Electrical Consumption
3,000PSI
9.0kW(4.5kW/side)
83A
10.5kW(5.25kW/side)
90A
14.0kW(7.0kW/side)
105A
PHDX-2, Three Phase, 208-240V
Pressure
Heater Size
Electrical Consumption
3,000PSI
9.0kW(4.5kW/side)
50A
10.5kW(5.25kW/side)
53A
14.0kW(7.0kW/side)
62A
PHDX-2, Three Phase, 400V
Pressure
Heater Size
Electrical Consumption
3,000PSI
9.0kW(4.5kW/side)
34A
10.5kW(5.25kW/side)
36A
14.0kW(7.0kW/side)
41A
Material Heater Power
Power Consumption
4.50kW/side(3x1500W/side)
9.0kW
5.25kW/side(3x1750W/side)
10.5kW
7.0kW/side(4x1750W/side)
14.0kW
Hose Transformer
Power Consumption
70V
2kVA
90V
3kVA
120V
5kVA
Electrical Motor
Power Consumption
PHDX-2
3hp
CAUTION!
Inside the console is a Terminal Strip for connecting the
main power (wire not supplied) to the PHD Series Proportioner. This
electrical connection must be made only by a qualified electrician.
REVISION 1.1
11