0000111659/150418/B MobileGo
EN - 9
Symptom
Problem
Possible
cause
Solution
The fan does
not start
The unit does
not function
No mains
voltage
Connect the mains
voltage
Thermal
overload
protection is
activated
-
Examine the fan
and motor to find
the cause and
remedy the
problem
- Push the red
button behind the
front panel to
reset. Refer to
The mains cord
is defective
Repair or replace
the mains cord
Loose contacts
Repair the contacts
Motor defective
Repair or replace
the motor
The green
LED is on but
the fan does
not run
The unit does
not function
Relay is
defective
Replace the relay
Thermal relay is
defective
Replace the thermal
relay
Motor defective
Repair or replace
the motor
Poor
extraction
capacity
The unit does
not function
properly
The shut-off
damper in the
hood of the
extraction arm
is (partly)
closed
(Fully) open the
shut-off damper
Clogged filters
& loose
connection of
pressure sensor
Repair the
connection of the
pressure tubes
Clogged filters
& defective
pressure sensor
Replace the
pressure sensor &
the pre filter
cassette
Replace the HEPA
filter cassette as
well
The buzzer
emits an
acoustic
signal
Poor
extraction
capacity
The pre filter is
clogged
Replace the pre
filter cassette
The HEPA filter
is clogged
Replace the HEPA
filter cassette
The
extraction
arm does not
stay in the
desired
position
Escape of
fume; no
proper
extraction
Friction setting
is not correct
Adjust the friction;
refer to Fig. V on
page 52 for the
adjustment points
You cannot
get the arm
in the desired
position
8
SPaRE PaRTS
8.1
Filter unit
The following spare filters are available for the filter unit;
-
refer to exploded view Fig. VIII on page
8.2
Extraction arm
The following spare parts are available for the extraction arms;
-
hose tube arm (EconomyArm): refer to exploded view Fig. VI
-
metal tube arm (KUA): refer to exploded view Fig. VII on
9
ELECTRiCaL DiaGRaM
Refer to the separately supplied electrical diagram.
10
DiSPoSaL
Dismantling and disposal of the unit must be done by qualified
persons.
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves when you dismantle and dispose of
the unit.
10.1 Dismantling
To safely dismantle the unit, obey the safety instructions that
follow.
Before dismantling of the unit:
-
disconnect it from the mains
- clean the outside
During dismantling of the unit:
-
make sure that the area is sufficiently ventilated, e.g. by a
mobile ventilation unit
After dismantling of the unit:
- clean the dismantling area
10.2 Disposal
Dispose of the pollutants and dust, together with the used
filters, in a professional manner in accordance with federal,
state or local regulations.
CE DECLaRaTioN
CE declaration of conformity for machinery
We, Plymovent Manufacturing B.V., Koraalstraat 9, 1812 RK
Alkmaar, Netherlands, herewith declare, on our own
responsibility, that the products:
- MobileGo
- MobileGo
plus
which this declaration refers to, are in accordance with the
conditions of the following Directives:
-
Machine Directive 2006/42 EC
- EMC 2014/30 EU
- LVD 2014/35 EU
-
ErP Directive 2009/125 EC
Signature:
Name:
M.S.J. Ligthart
Position:
Product Manager
Date of issue: 1st May 2018