Plymovent MDB-DILUTER PRO Installation And User Manual Download Page 6

0000300349/230420/0 MDB-Diluter PRO 

5

Users

 

- The use of this product is exclusively reserved to authorised, 

trained and qualified users. Temporary personnel and 

personnel in training can only use the product under 

supervision and responsibility of skilled engineers. 

 

- Stay alert and keep your attention to your work. Do not use 

the product when you are under the influence of drugs, 

alcohol or medicine. 

 

- The product is not to be used by children or persons with 

reduced physical, sensory or mental capabilities, or lack of 

experience and knowledge, unless they have been given 

supervision or instruction. 

 

- Children must be supervised not to play with the product.

Intended use

5

The MDB-Diluter has been designed exclusively for extracting 

and filtering gases and particles which are released during the 

most common welding processes.

The ControlPro has been designed exclusively as control 

equipment for use with a filter system type MDB-Diluter of 

Plymovent including the connected extraction fan. 

Using the product for other purposes is considered contrary to 

its intended use. The manufacturer accepts no liability for any 

damage or injury resulting from such use. The product has 

been built in accordance with state-of-the-art standards and 

recognised safety regulations. Only use this product when in 

technically perfect condition in accordance with its intended 

use and the instructions explained in the user manual.

Technical specifications

The specifications given in this manual must not be altered.

Modifications

Modification of (parts of) the product is not allowed.

Product combinations

If the product is used in combination with other products or 

machines, the safety instructions in the documentation of 

these products also apply.

WARNING!

Fire hazard! Do 

not

 use the product for:

 

-

extracting and/or filtering flammable, glowing or 

burning particles or solids or liquids

 

-

extracting and/or filtering of aggressive fumes 

(such as hydrochloric acid) or sharp particles

 

-

extracting and/or filtering dust particles which are 

released when welding surfaces treated with 

primer

 

- sucking cigarettes, cigars, oiled tissues, and other 

burning particles, objects, and acids

WARNING

Do 

not

 use the product for:

 

- oil mist

 

- paint mist

 

- extraction of hot gases (more than 45°C/113°F 

continuously)

 

- explosive environments or explosive substances/

gases

Note: this list is not all-embracing.

5.  “Intended use” as explained in EN-ISO 12100-1 is the use for which the 

technical product is suited as specified by the manufacturer, inclusive of his 

directions in the sales brochure. In case of doubt it is the use which can be 

deduced from the construction, the model and the function of the technical 

product which is considered normal use. Operating the machine within the 

limits of its intended use also involves observing the instructions in the user 

manual.

Installation

 

- The installation of this product is exclusively reserved to 

authorised, trained and qualified engineers.

 

- Electric connection to be executed in accordance with local 

requirements. Ensure compliance with the EMC regulatory 

arrangements. 

 

- During installation, always use Personal Protective 

Equipment (PPE) to avoid injury. This also applies for persons 

who enter the work area during installation.

 

-

Use sufficient climbing gear and safety guards when working 

on a higher level than 2 meter (6.5 ft) (local restrictions may 

apply). 

 

- Do not install the product in front of entrances and exits 

which must be used for emergency services. 

 

- Mind any gas and water pipes and electric cables.

 

- Make sure that the wall, ceiling or support system are strong 

enough to carry the product.

 

- Ensure the workspace is well illuminated. 

 

- Use common sense. Stay alert and keep your attention to 

your work. Do not install the product when you are under the 

influence of drugs, alcohol or medicine. 

 

- Make sure that the workshop, in the vicinity of the product, 

contains sufficient approved fire extinguishers (suitable for 

fire classes ABC). 

 

- Air containing particles such as chromium, nickel, beryllium, 

cadmium, lead etc., which is a health hazard, should never 

be recycled. This air must always be brought outside the 

working area.

Use

 

- Inspect the product and check it for damage. Verify the 

functioning of the safety features. 

 

- During use, always use Personal Protective Equipment (PPE) 

to avoid injury. This also applies for persons who enter the 

work area.

 

- Check the working environment. Do not allow unauthorised 

persons to enter the working environment. 

 

- Protect the product against water and humidity.

 

-

Make sure the room is always sufficiently ventilated; this 

applies especially to confined spaces.

Service, maintenance and repairs

 

- Obey the maintenance intervals given in this manual. 

Overdue maintenance can lead to high costs for repair and 

revisions and can render the guarantee null and void. 

 

- During service, maintenance and repair jobs, always use 

Personal Protective Equipment (PPE) to avoid injury. This 

also applies for persons who enter the work area.

 

- Always use tools, materials, lubricants and service 

techniques which have been approved by the manufacturer. 

Do not use worn tools and do not leave any tools in or on the 

product. 

 

- Safety features which have been removed for service, 

maintenance or repairs, must be put back immediately after 

finishing these jobs and it must be checked that they still 

function properly. 

 

-

Use sufficient climbing gear and safety guards when working 

on a higher level than 2 meter (6.5 ft) (local restrictions may 

apply).

ATTENTION

Service, maintenance and repairs should only be 

performed in accordance with directive TRGS 560 by 

authorised, qualified and trained persons (skilled) 

using appropriate work practices.

Summary of Contents for MDB-DILUTER PRO

Page 1: ...www plymovent com Environmental diluter system Installation and user manual MDB DILUTER PRO EN...

Page 2: ...document and is therefore subject at any time to change or amendment and the right to change or amend is hereby expressly reserved The instructions in this publication only serve as a guideline for in...

Page 3: ...oduct The product consists of various components the identification plates of which contain the following data product name serial number supply voltage and frequency power consumption 1 2 General des...

Page 4: ...eptacle with dust cap ethernet 10 100 Mbit s RJ45 shielded with dust cap Display size type brightness colour resolution 7 resistive touch screen 300 cd m 262K 800 x 480 pixels Approvals certificates C...

Page 5: ...nnected extraction fan It contains an extensive feature package to monitor and arrange the RamAir pulse amplifier filter cleaning system the required airflow and the corresponding fan speed By means o...

Page 6: ...g the machine within the limits of its intended use also involves observing the instructions in the user manual Installation The installation of this product is exclusively reserved to authorised trai...

Page 7: ...2 Seal set MDB BM 4 3 Spare seal set MDB SealApplicator 6 E g heat gun cable stripping tool 7 The type of mounting material depends on the wall type 8 Number and type of cables depend on the selected...

Page 8: ...Air outlet module Fig 4 3 Temporary disassemble the back side of the frame to put the outlet module on the frame Fig 4 3 Air outlet module on frame Fig 4 4 Slightly lift the outlet module and put the...

Page 9: ...art with a long seal 1046 mm Try to avoid touching the sticky side with your fingers Make sure that you attach the seal in the centre of the frame edges and that the jigsaws fit together Peel approx 5...

Page 10: ...ably remove the remains of glue if any from the filter module e g with sticker remover Make sure that you do not damage the undamaged seals Apply a spare seal according to the above instructions ATTEN...

Page 11: ...seals 2 Put 4 positioning studs in the upper cage nuts of the first filter module corner positions 3 Spray SealApplicator lubricant on the seals 4 Put another filter module A within 60 seconds on the...

Page 12: ...compressed air switch B Connect the loose end of the pneumatic hose to the compressed air switch B via the T connector Install a compressed air regulator CAR KIT or similar C on the mounting frame Set...

Page 13: ...Attach the dustbin to the hopper with the quick connect clamp B Fig 4 26 A B C D Dustbin 4 9 1 Extraction fan Fig 4 27 Put the extraction fan on the fan frame Fig 4 27 A B Fan on frame In the standar...

Page 14: ...ermine the direction of the outlet unit and the airflow direction of the individual nozzles Depending on the specific circumstances it might be necessary to partly or fully close one or more nozzles F...

Page 15: ...filter compartment 3 Put the other hose through the connection Fig 4 33 1 2 3 Cable glands and pneumatic hoses Fig 4 34 Make sure to have approx 25 mm 1 in A B hose end Tighten all cable glands Fig 4...

Page 16: ...e gland M16 for the PTC cable C Cable gland M25 for the mains cord Low voltage compartment right bottom plate D Universal cable glands M16 4 E Push in fittings 3 for the pressure tubes20 Fig 4 38 A B...

Page 17: ...remain unused The PC board contains detachable screw terminal blocks connectors Table I on page 32 gives an overview of the necessary and optional cables22 that you need to install the system WARNING...

Page 18: ...Fasten the cable gland A B PE Fig 4 43 Mains cord 23 PE Protective Earth 4 12 2 Motor cable PTC cable To install the motor cable and PTC cable to the Panel do the following Fig 4 44 Put the motor cab...

Page 19: ...t 6 12 1 24V 2 IN 6 3 24V 4 IN 7 5 24V 6 IN 8 7 24V 8 IN 9 9 24V 10 IN 10 11 24V 12 IN 11 13 24V 14 IN 12 15 COM2 16 GND CAN Slave 1 2 CAN_H 3 CAN_L 4 GND 5 SHD 24V 1 2 A 3 B 4 GND 5 SHD RS485 VFD Fil...

Page 20: ...y closed Max connection 30 VDC 2 5 A per relay If desired connect Relay 1 and or Relay 2 to an external device You must select the specific event that you want to activate the relay s on the HMI refer...

Page 21: ...00 m h 885 CFM 9000 m h 5300 CFM 50 Hz For more detailed information refer to Fig X on page 31 Fig XI shows the horizontal throw per nozzle 5 3 1 PID setpoint of the fan pressure To determine and set...

Page 22: ...aintenance The system has been designed to function without problems for a long time with a minimum of maintenance In order to guarantee this some simple regular maintenance and cleaning activities ar...

Page 23: ...7 1 Turn off the main switch on the Panel to de energize the entire system Disconnect the compressed air supply Loosen the drain valve A to empty the compressed air tank Tighten the drain valve Fig 7...

Page 24: ...or both inspection covers Remove the inspection cover s Clean the inside of the module preferably with an industrial vacuum cleaner and a non agressive detergent Install the inspection cover s Fig 7...

Page 25: ...lack screen HMI does not function Loose connection Tighten the HMI cable to the CAN connector refer to Fig 4 41B C Loose or incorrectly connected cable Connect the HMI cable to the CAN HMI connector r...

Page 26: ...ctives Machine Directive 2006 42 EC LVD 2014 35 EU Low Voltage Directive Harmonised Standards EN IEC 60204 1 2006 Safety of machinery Electrical equipment of machines Part 1 General requirements EN IE...

Page 27: ...s MDB Diluter A B C D E F G H J K L M mm inch A 2095 82 5 B 897 35 3 C 1100 43 3 D 1312 51 7 E 1100 43 3 F 1124 44 3 G 3649 143 7 H 2072 81 6 I 803 31 6 J 1442 56 8 K 4945 194 7 M 1422 56 0 Fig II Dim...

Page 28: ...r PRO 27 ANNEX Fig III Air circulation Welding fume is mixed at source so optimum dilution Concentration of welding fume instead of dilution Example position of two systems Dilution filtration of a sp...

Page 29: ...ark arrester A Fig IV Overview of pneumatic and electric connections Ref Cable E Electric P Pneumatic For connection of To 1 Panel HMI E Panel HMI 5 Mains cord E Panel Mains 20 Control cable E Compres...

Page 30: ...00102666 Lid for filter cartridge CART MDB 0000102675 Filter cartridge holder MDB 0000103150 Magnetic valve 1 inch incl 24V DC coil and 3 m cable 0000104642 CART PTFE 15 Filter cartridge 0000110329 Se...

Page 31: ...0103139 Switch mode power supply 24V DC 2 5A 0000113558 Indicator light yellow 24V 0000113559 PCB main board ControlPro 0324000300 Indicator light white 24V 0324000310 Indicator light green 24V 032400...

Page 32: ...Correctie NR NR 0 NR 2 315 0 018 400 0 038 qv m3 h LT 10o vf m s VT m s VT LT m VT final velocity of throw Vf velocity at outlet of nozzle LT throw at VT qV air volume per nozzle Fig XI Horizontal thr...

Page 33: ...l alert input 8 Relay output 1 9 Relay output 2 20 Control cable compressed air switch H05VV F 2X0 75 22 Light tower H05VV F 7X0 5 23 Motor cable 190 CY 4X4 shielded 24 PTC cable 190 CY 2X0 75 shielde...

Page 34: ...www plymovent com 0000300349 230420 0 MDB Diluter PRO...

Reviews: