0000104046
/150915/0 MultiDust Bank COMPACT
EN - 8
• Insert the 4 screw studs (A) in the bottom of the unit.
• Attach them to the platform or frame with the 4 locknuts
(B).
• Make sure that the unit is level.
Fig. 4.1
A (4x)
B (4x)
Mounting on platform or frame (image of frame indicative
only)
4.5
Filter cartridges
To install the filter cartridges, proceed as follows.
• Loosen the star knob (F) and disassemble the cover plate
(E), the nut (D) and the metal washer (C).
• Put the filter cartridge (B) on the cartridge holder (A).
• Install the removed parts in reverse order.
Fig. 4.2
B
A
D
C
E
F
Installation of the filter cartridges
ATTENTION
Make sure that the front of the filter cartridge
aligns
*)
with the filter housing, so that the lid closes
well. If this is not the case, the filter cartridge is not
positioned correctly. This can cause leakage and less
efficient operation of the filter cartridge.
*)
tolerance: max. 2 mm (0.1 in.)
>2 mm
max. 2 mm
>2 mm
max. 2 mm
>2 mm
max. 2 mm
>2 mm
max. 2 mm
• Do the same procedure for the remaining filter
cartridge(s).
4.6
Electric connection
cAUTION!
The electric connection must be executed in
accordance with the local requirements. Ensure
compliance with the EMC regulatory arrangements.
To be sourced locally:
*) cable
cable
specifications
For
connection
of:
To:
A Mains cable
single phase + earth
1 mm² (3G1/
AWG18)
FilterControl
panel
the mains
Mains cable
three-
earth 4 mm² (4G4/
AWG10)
frequency
inverter or
other start/
stop device
the mains
Fan cable
three-
earth 4 mm² (4G4/
AWG10) (shielded
cable)
fan motor
frequency
inverter or
other start/
stop device
PTC cable
2-cored 0,75 mm²
(2xAWG18) (shielded
cable)
fan motor
frequency
inverter or
other start/
stop device
B Connection
cable
2-cored 0,75 mm²
(2xAWG18) (shielded
cable)
PLC
frequency
inverter or
other start/
stop device
C
Connection
cable
8-cored (including
earth wire) 0,75
mm² (8xAWG18),
PVC outer sheath
filter unit
FilterControl
panel
D Connection
cable
2-cored 0,75 mm²
(2xAWG18)
pressure
transmitter
FilterControl
panel
*) Corresponds with the cable glands indicated in Fig. 4.3
4.6.1 FilterControl panel
The FilterControl panel must be installed at a clearly visible
and accessible position.