background image

 

8.3.8

 

Antifreeze 

The  main  controller  works  with  a  constant 
preset  temperature  set  in  the  following 
menu:  
Temperature  settings 

  Antifreeze 

temperature 
Activation of this mode will additionally result 
in setting a preset temperature of hot utility 

water  on  the  controller  to  8°C.  The 

 

symbol is displayed on the panel screen. 

8.3.9

 

Loading HUW 

This  mode  enables  loading  the  HUW 
container once. After this mode is activated, 
its  duration  has  to  be  set  within  a  range  of 
1÷60 h, in 1 h increments. During the period 
in  which  this  mode  is  active,  night 
temperature  decreases  set  in  schedules  for 
the HUW container and circulation pump are 
inactive. 

8.4

 

Schedule 

Menu  enables  programming  time  schedules 
for  room  panels,  HUW  container  and 
operation  of  the  circulating  pump.  It  is 
possible  to  set  time  schedules  for  every 
weekday  separately  with  an  accuracy  of  0.5 
h  (48  changes  of  temperature  during  one 
day). The main controller enables setting two 
temperature  levels:  day  (comfort)  and  night 
(economic). Schedules can be edited in the:  
Menu 

 Schedule 

 

Select  a  weekday  for  which the  schedule 
will be set / modified.  

 

Schedule 

edition 

window 

will 

be 

displayed. 

  
 

 

 
 
1-time  period  line,  2-currently  edited  time 
period, 3  – night temp., 4  – day temp, 5,7-
time  period  selection,  6-temp.  selection.,  8- 
entering schedules copying menu. 
In order to set the required time period: 

 

set the indicator “2” to a starting hour of 
time zone with the use of buttons, 

 

set the comfort (day) or economic (night) 

temperature with the use of 

 button, 

 

set the indicator “2” to an ending hour of 
time zone with the use of buttons, 

 

press 

 button in order to finish editing 

the zone, 

 

the  aforementioned  actions  can  be 
repeated  for  other  time  period,  if 
required, 

 

press 

  button  in  order  to  display 

window  for  copying  the  set  schedule  to 
any weekday. 

8.5

 

Temperature settings  

Enables changing preset temperatures inside 
the compartment: 

 

Day temperature (comfort)

 

Night temperature (economic), 

 

Antifreeze temperature

8.6

 

Boiler 

Enables  remote  access  to  boiler  controller 
menu  which  the  wireless  room  panel  is 
connected  to.  It  is  possible  to  preview  and 
edit  all  parameters  and  alarms  available  in 
the main controller.  

8.7

 

HUW 

Enables  setting  a  preset  temperature  and 
operation mode of the HUW container.   

8.8

 

Summer/Winter 

Enables changing the “Summer/Winter” work 
mode in the boiler controller.   

8.9

 

Boiler On/Off 

Enables  remote  activation  or  deactivation  of 
the  boiler  controller  from  the  wireless  room 
panel. 

 

Menu  positions:  Boiler,    HUW, 
Summer/Winter
  and  Boiler  On/Off 
are  optional  and  available  only  in 
case  of  connecting  the  wireless 
room  panel  to  the  main  controller 
with compatible software. 

8.10

 

Notifications 

concerning 

controller alarms 

Wireless  room  panel  displays  the  alarms 
transmitted  by  the  main  controller  and 
reports them using a sound signal. Touch the 
screen  in  order  to  turn  off  the  active  alarm. 

Summary of Contents for eSTER x80

Page 1: ...ISSUE 1 1_EN WIRELESS ROOM PANEL eSTER_x80 FOR HEATING CIRCUIT CONTROLLERS 06 2019 ISM_xSMART the ISM_xSMART radio module is standard equipment for the wireless room panel ONLY COOPERATES WITH ecoMAX...

Page 2: ......

Page 3: ...NTROLLER ALARMS 7 8 11 SETTINGS 8 8 11 1 Hysteresis 8 8 11 2 Temperature correction 8 8 11 3 Screen brightness 8 8 11 4 Changing the language 8 8 11 5 PARENTAL LOCK 8 8 11 6 SOFTWARE UPDATE 8 8 11 7 S...

Page 4: ...ly industrialized buildings 3 Applied symbols In this manual the following graphic symbols are used the symbol indicates additional advice and information the symbol indicates important information Ca...

Page 5: ...sition from the menu The symbols mean w selection of the main Menu decrease increase the value of the selected parameter scroll the parameters list up down exit a chosen Menu position or cancel a para...

Page 6: ...ode in which it has been operating before the Out of home mode was set The symbol is displayed on the panel screen 8 3 5 Airing Selection of this mode will result in closing the mixing valves and swit...

Page 7: ...time period set the indicator 2 to a starting hour of time zone with the use of buttons set the comfort day or economic night temperature with the use of button set the indicator 2 to an ending hour o...

Page 8: ...8 11 6 Software update Enables updating the software with the use of a microSDHC memory card inserted into a slot in the panel enclosure in all connected devices controller additional modules control...

Page 9: ...iring function with the radio module for 4 minutes The correct pairing will be confirmed by a message on the screen of the wireless room panel 8 11 13 Information The Information menu displays the str...

Page 10: ...main controller socket using a 2 wire cable which should be connected in accordance with point 12 omitting the connection of the D and D signals To connect the room panel power supply you can use a 2...

Page 11: ...he pairing mode will be activated for 4 minutes during this time the room panel with the radio module should be paired in accordance with point 8 11 12 During the active pairing mode you can pair in t...

Page 12: ...els is possible only when the radio module program is fully compatible with the main controller To check if the main controller program is fully compatible with the radio module select the tab in the...

Page 13: ...adio module 2 main controller Connection of the module to the ecoMAX860P1 P2 D1 D2 1 radio module 2 main controller Connection of the module to the ecoMAX860P3 D3 1 radio module 2 main controller Conn...

Page 14: ...e main controller is equipped with TOU CH control panel colored with a touch panel only one room panel can be supplied directly from the controller module terminal 31 Panels 2 and 3 have to be supplie...

Page 15: ...TOUCH type panels simultaneously If the main controller is equipped with a standard control panel version with a knob two room panels can be supplied directly from the controller module terminal 46 T...

Page 16: ...equipped with TOUCH control panel colored with a touch panel only one room panel can be supplied directly from the controller module socket G4 Panels 2 and 3 have to be supplied by the additional pow...

Page 17: ...e supplied by the additional power adapter 12 VDC min 0 5 A Connection with ecoMAX910R1 ecoMAX920P1 If the main controller is equipped with a standard control panel version with a knob or TOUCH contro...

Page 18: ...5 868 MHz Transmission power of the wireless room panel and radio module 20 mW 13 dBm Radio network topology One radio module and many subordinate room panels Display Graphic 480 x 272 pix with touch...

Page 19: ......

Page 20: ...ul Wsp lna 19 Ignatki 16 001 Kleosin Poland plum plum pl www plum pl...

Reviews: