Plum eSTER x80 Installation And Operating Manual Download Page 4

 

1.

 

Recommendations regarding safety 

The following requirements shall be complied 
with. 

 

 

The  device  should  be  used  as  intended, 
keeping  it  in  a  dry  environment,  and 
installing it only indoors. 

 

Before  connecting  the  radio  module  to 
the  main  controller,  absolutely  stop  the 
operation  of  the  main  controller  by 
switching it off and disconnecting it from 
the main power supply. 

 

Non-compliant  with  the  manual  or 
incorrect  connection  of  the  radio  module 
to the main controller may be a source of 
malfunction  of  the  main  controller  and 
the radio module itself. 

 

The device should only be started up by a 
person  who  is  familiar  with  these 
instructions. 

 

Under  no  circumstances  may  the  device 
construction be modified. 

2.

 

General information 

The  wireless  room  panel  is  designed  for 
wireless  cooperation  with  external  radio 
transmission  module,  which  is  wired  to  the 
main  controller.  The  room  panel  is  installed 
in a selected room, e.g. a living room, and is 
designed  to  maintain  a  preset  room 
temperature  by  sending  a  radio  signal  to  a 
module connected to the main controller. The 
implemented  encrypted,  two-way  radio 
communication  allows  the  transmission  of 
information  from  the  main  controller  to  the 
room panel, so the room panel itself acts as 
an  additional  screen  for  servicing  all 
parameters of the main controller. 

 

Radio  communication:  1  –  eSTER_x80  wireless 
room  panel,  2  –  ISM_xSMART  radio  module,  3  - 
main controller. 

 

Wireless  room  panel  can  be  used  in  a 
household  or  similar  environments  and  in 
slightly industrialized buildings. 

3.

 

Applied symbols 

In this manual the following graphic symbols 
are used: 

  -  the  symbol  indicates  additional 

advice and information. 

  -  the  symbol  indicates  important 

information. 
Caution:  the  symbols  indicate  important 
information,  in  order  to  make  the  manual 
more user friendly. Yet, this does not exempt 
the  user  from  the  obligation  to  comply  with 
requirements  which  are  not  marked  with  a 
graphic symbol. 

4.

 

Information about documentation 

The  wireless  room  panel  manual  is  a 
supplement  for  the  main  controller  manual. 
In  particular,  except  for  this  manual,  the 
main  controller  manual  should  also  be 
followed. Manufacturer  is not responsible for 
any  damages  caused  by  failure  to  following 
these instructions. 

5.

 

Storage of documentation 

This assembly and operation manual, as well 
as  any  other  applicable  documentation, 
should  be  stored  diligently,  so  that  it  is 
available at any time. In the case of removal 
or  sale  of  the  device,  the  attached 
documentation should be handed over to the 
new user. 

6.

 

Declaration of Conformity 

The 

purchased 

product 

meets 

the 

requirements  of  Directive  2014/53/EU  of 
the  European  Parliament  and  of  the 
Council  of  16  April  2014  
on  the 
harmonization  of  the  laws  of  the  Member 
States  concerning  making  available  on  the 
market  of  radio  equipment  and  does  not 
cause  harmful  interference  with  radio 
communications  to  other  equipment,  in  a 
residential area, provided that the product is 
correctly  installed  and  used  in  accordance 
with the requirements of this manual. 

7.

 

Directive WEEE 2012/19/UE 

Purchased  product  is  designed  and  made  of 
materials of highest quality. 
The  product  meets  the  requirements  of  the 
Directive 2012/19/EU of 4 July 2012 on 

Summary of Contents for eSTER x80

Page 1: ...ISSUE 1 1_EN WIRELESS ROOM PANEL eSTER_x80 FOR HEATING CIRCUIT CONTROLLERS 06 2019 ISM_xSMART the ISM_xSMART radio module is standard equipment for the wireless room panel ONLY COOPERATES WITH ecoMAX...

Page 2: ......

Page 3: ...NTROLLER ALARMS 7 8 11 SETTINGS 8 8 11 1 Hysteresis 8 8 11 2 Temperature correction 8 8 11 3 Screen brightness 8 8 11 4 Changing the language 8 8 11 5 PARENTAL LOCK 8 8 11 6 SOFTWARE UPDATE 8 8 11 7 S...

Page 4: ...ly industrialized buildings 3 Applied symbols In this manual the following graphic symbols are used the symbol indicates additional advice and information the symbol indicates important information Ca...

Page 5: ...sition from the menu The symbols mean w selection of the main Menu decrease increase the value of the selected parameter scroll the parameters list up down exit a chosen Menu position or cancel a para...

Page 6: ...ode in which it has been operating before the Out of home mode was set The symbol is displayed on the panel screen 8 3 5 Airing Selection of this mode will result in closing the mixing valves and swit...

Page 7: ...time period set the indicator 2 to a starting hour of time zone with the use of buttons set the comfort day or economic night temperature with the use of button set the indicator 2 to an ending hour o...

Page 8: ...8 11 6 Software update Enables updating the software with the use of a microSDHC memory card inserted into a slot in the panel enclosure in all connected devices controller additional modules control...

Page 9: ...iring function with the radio module for 4 minutes The correct pairing will be confirmed by a message on the screen of the wireless room panel 8 11 13 Information The Information menu displays the str...

Page 10: ...main controller socket using a 2 wire cable which should be connected in accordance with point 12 omitting the connection of the D and D signals To connect the room panel power supply you can use a 2...

Page 11: ...he pairing mode will be activated for 4 minutes during this time the room panel with the radio module should be paired in accordance with point 8 11 12 During the active pairing mode you can pair in t...

Page 12: ...els is possible only when the radio module program is fully compatible with the main controller To check if the main controller program is fully compatible with the radio module select the tab in the...

Page 13: ...adio module 2 main controller Connection of the module to the ecoMAX860P1 P2 D1 D2 1 radio module 2 main controller Connection of the module to the ecoMAX860P3 D3 1 radio module 2 main controller Conn...

Page 14: ...e main controller is equipped with TOU CH control panel colored with a touch panel only one room panel can be supplied directly from the controller module terminal 31 Panels 2 and 3 have to be supplie...

Page 15: ...TOUCH type panels simultaneously If the main controller is equipped with a standard control panel version with a knob two room panels can be supplied directly from the controller module terminal 46 T...

Page 16: ...equipped with TOUCH control panel colored with a touch panel only one room panel can be supplied directly from the controller module socket G4 Panels 2 and 3 have to be supplied by the additional pow...

Page 17: ...e supplied by the additional power adapter 12 VDC min 0 5 A Connection with ecoMAX910R1 ecoMAX920P1 If the main controller is equipped with a standard control panel version with a knob or TOUCH contro...

Page 18: ...5 868 MHz Transmission power of the wireless room panel and radio module 20 mW 13 dBm Radio network topology One radio module and many subordinate room panels Display Graphic 480 x 272 pix with touch...

Page 19: ......

Page 20: ...ul Wsp lna 19 Ignatki 16 001 Kleosin Poland plum plum pl www plum pl...

Reviews: