Installer menu - structure
Service configuration confirmation
Filter setting
Dirt det. mechanism - supply*
•
None, Time, Pressure switch,
Pressure sensor
Dirt det. mechanism - exhaust*
•
None, Time, Pressure switch,
Pressure sensor
Filter classes parameters:
•
Standard class:
➢
Filter class
➢
Initial resistance
➢
Final resistance
➢
Dirt alarm
➢
Central emergency mode
•
Medium class (as above)
•
Accurate class (as above)
•
Filter classes default settings (yes/no)
Detection mechanism:
•
Timed mechanism*
•
Days to alarm
•
Days to emergency mode
•
Detection by pressure switches*
•
Logical state
– air supply filter
(NC/NO)
•
Logical state
– exhaust filter (NC/NO)
•
Air supply filter worn out alarm
•
Air supply filter lifetime
•
Air supply filter emergency mode on
•
Exhaust filter worn out alarm
•
Exhaust filter lifetime
•
Exhaust filter emergency mode on
•
Dirt test delay*
•
Dirt test adjustment*
•
Filters maintenance:
•
Override filters replacement
procedure
•
Filters replacement by user
•
Air supply filter operation time
reset
•
Exhaust filter operation time reset
•
Emergency mode
– turning on
central
•
Emergency mode -air supply fan
•
Emergency mode
– exhaust fan
•
Dirt test frequency
•
Testing day
•
Dirt testing hour
•
Dirt test override
Manual control
Air supply and exhaust control
Control type
•
Standard, Constant pressure, Constant
expenditure
Information
IN1/IN2 input settings
IN1/IN2 inputs work mode
•
None, Hood, Filters pressure switches,
Air quality sensor
Logic state IN1
Logic state IN2
Hood mode settings:
•
Air supply control IN1
•
Exhaust control from IN1
•
Air supply control IN2
•
Exhaust control from IN2
Air quality sensor:
•
Sensor logical state
•
Fans velocity
•
Maintaining alarm duration
GHE/Mix. chamber/Cooler settings
GHE support
•
Yes, No
Mixing chamber support
•
Yes, No
Cooler support
•
Yes, No
GHE Sensor
•
Yes, No
•
•
•
Heaters
Secondary heater type:
•
None, Digital electric, Analog electric,
Digital water, Analog water
Primary heater support:
•
None, Digital electric, Analog electric,
Digital water, Analog water
Primary heater thermostat:
•
Normally opened, Normally closed
Secondary heater thermostat:
•
Normally opened, Normally closed
Minimum air supply fan flow*
Air quality sensor
Air quality sensor support:
•
None, Humidity sensor, CO
2
sensor
CO
2
detection level*
CO
2
detection level hysteresis*
CO
2
sensor range*
Humidity sensor detection level*
The menu is available after entering the service
password. Depending on controller configuration
and whether it is on or off, some of menu
parameters might be unavailable. These are
marked with “*”.
Summary of Contents for ecoVENT MIDI
Page 6: ...6...
Page 7: ...7 USER MANUAL ecoVENT MIDI...
Page 20: ...20...
Page 25: ...25...
Page 26: ...26 INSTALLATION AND SERVICE SETTINGS ecoVENT MIDI...
Page 56: ...56...
Page 57: ...57 Assembly dimensions of the MIDI module...
Page 58: ...58...
Page 59: ...59...
Page 60: ...60...