7
Set the comfort (day) or economic
(night) temperature with the use of
button.
Set the indicator “2” to an ending hour of
time zone with the use of
<
,
>
buttons,
Press
button in order to finish editing
the zone,
The aforementioned actions can be
repeated for other time period, if required
Press
button in order to display
window for copying the set schedule to
any weekday.
3.5
Temperature settings
Enables changing
preset temperatures
inside the compartment:
Day temperature (comfort)
,
Night temperature (economic)
,
Anti-freeze temperature
.
3.6
Boiler
Boiler
– enables remote access to boiler
controller menu which the room panel is
connected to. It is possible to preview and
edit all parameters and alarms available in
the ecoMAX boiler controller.
3.7
HUW
HUW
-
enables setting a preset
temperature and work mode of the hot
utility water tank.
3.8
Summer/Winter
Summer/Winter
- enables changing the
“Summer/Winter” work mode in the boiler
controller.
3.9
Boiler on/off
Boiler on/off
– enables remote
activation or deactivation of the boiler
controller from the room thermostat.
Menu positions:
Boiler
,
HUW,
Summer/Winter
and
Boiler on/off
are optional and available only in
case of connecting the ecoSTER
TOUCH panel to the controller with
compatible software.
3.10
Boiler controller remote screen
If the boiler controller is equipped with a
standard control panel (version with a knob),
the ecoSTER TOUCH room panel will display
a precise graphic image of the controller
main screen (remote screen) on one of the
main screens. Menu position is selected by
pressing
<
|
|
>
symbols on the screen.
For safety reasons, not all controller menu
positions will be available.
3.11
Notifications
concerning
controller alarms
Room panel displays the alarms transmitted
by the boiler controller and reports them
using a sound signal. Touch the screen in
order to turn off the active alarm. The alarm
will not be deleted. For safety reasons, this
can be done only via the boiler controller.
3.12
Settings
Menu
→
Settings
→ ………
3.12.1
Hysteresis
This parameter defines temperature
hysteresis inside the compartment. Boiler
controller
will
begin
heating
when
temperature inside the compartment drops
below the current preset temperature minus
hysteresis. Heating will end up when the
current preset temperature inside the
compartment is reached.
3.12.2
Temperature correction
Enables entering a correction of
thermostat measured temperature within a
range of -4.0°C to +4.0°C.