10
4.
ASSEMBLY
4.1
Technical data
Power supply/consumed
current
+12VDC/150mA
Protection class
IP20
Work/storage temperature
0..50/0..65 C
Temperature
measurement/regulation range
0..50/5..35 C
Hysteresis
0.2..5 C
Relative humidity
5 - 85%, without
condensation
Display
graphic, touch
Dimensions
148x97x23 mm
Weight
0.2 kg
Standards
PN-EN 60730-2-9
PN-EN 60730-1
Software class
A
4.2
Exploitation conditions
do not expose the device to direct
influence of atmospheric conditions (rain,
sunlight) nor vibrations stronger than
typical
occurring
during
wheel
transportation.
do not use the device in vapor
condensation conditions and protect it
from water.
storage and transportation temperature
should not exceed the range of -15…65
°C.
install the device only in dry residential
room.
4.3
Assembly requirements
Recommendations:
1.
Panel is intended for wall installation
inside compartments.
2.
Assemble the panel at a height of approx.
1.5 m above the floor.
3.
Avoid highly insolated areas with poor air
circulation, near heating devices and in
direct vicinity of doors and windows –
temperature measurement is disturbed
by external conditions.
4.
Panel should be installed by a qualified
installer.
Manufacturer bears no responsibility for
damages caused by non-observance of this
manual.
4.4
Assembly description
Drill holes in the wall (apply rawlplugs in
case of masonry wall) and screw the
screws in. Distance between holes is
given on the back side of the room panel
(90x43mm).
Execute electrical connection between the
panel/panels and the boiler controller
serving as its power source with the use
of electrical wire.
Wire can be flush or wall mounted.
Do not lead the connection wire along
with wires of electrical network in the
building. Wire cannot be located near
devices emitting strong electromagnetic
field.
Summary of Contents for ecoSTER TOUCH
Page 2: ......