21
Circulation support
ON
Pump Service Settings serwisowe
OPERATION mode: Return
Protection
OFF
Service Settings Boiler Settings Return Protection 4D
8.4
Schemat 4
Fig. 17 Diagram with heat buffer and additional module B
9
,
where:
1 – boiler, 2 – ecoMAXX regulator
– module A, 3 – ecoMAXX regulator – control panel, 4 – fan, 5 – feeder temperature sensor, 6 - gear-motor,
7 – boiler temperature sensor, 8 – HUW temperature sensor, 9 - mixer 1 temperature sensor, 10 –
temperature (weather) sensor, 12 – HUW circuit pump, 13 – mixer 1 circuit pump, 14 – mixer 1 servo, 15 –
HUW container, 16 – ecoSTER200 room control panel with room thermostat function, 17 – extension module
B, 27 – return temperature sensor, 28 – thermostatic 3-way valve (to protect boiler return), 29 - throttle
mushroom valve, 32 – HUW circulating pump, 34 – lower buffer sensor, 35 – upper buffer sensor, 36 – heat
buffer, 37 – additional solar ecoSOL regulator.
Parameter
Setting
MENU
OPERATION mode: Return Protection
OFF
Service Settings Boiler Settings Return
Protection 4D (if mixer sensor in not provided
- this option is not available)
Mixer support 1
ON (włącz.)
CO
Service Settings Mixer Settings 1
Max. preset temperature of mixer 1
75
Service Settings Mixer Settings 1
Heating curve. mixer 1
0.8 – 1.4
Service Settings Mixer Settings 1
Weather control mix.1
ON
menu Mixer Settings 1
Circulation support
ON
Pump Service Settings
Buffer Support
ON
Buffer service Settings
Buffer loading start temp.
40
Buffer Service Settings
Buffer loading end temp.
60
Buffer Service Settings
Min. buffer temp.
23
Buffer Service Settings
9
The presented hydraulic diagram does not replace central heating engineering design and may be used for information
purposes only.