7.5 Checking the Power Pack Oil Level Access™ EA & Access™ EAB
Before checking the Oil Level, ensure the lift is completely lowered- failure to do so could
cause a false reading- and overfilling with oil WILL cause permanent damage to the pump.
Wipe away any residual oil/ dirt from around the oil filler so that the level of oil can be
correctly seen. If the level has dropped below the 25mm limit then remove the filler cap
and top up slowly with PLS Blue oil ONLY, when the correct level is achieved then replace
the filler cap. Operate the lift several times and then repeat the checking process.
7.5 Checking the Power Pack Oil Level Access™ EA & Access™ EAB
FLOOR LEVEL
LIFT MUST BE IN FULLY LOWERED POSITION
BEFORE CHECKING OIL LEVEL
ENLARGED VIEW
SHOWING PUMP WITH COVER REMOVED
25MM MAX