Podiatry Chair User Manual 

14 | 

P a g e

 

 

8.

 

Guarantee and Service (UK only) 

Plinth Medical Ltd offer a 5 year parts guarantee on all Premium Range products 
delivered from January 2013 and a lifetime frame guarantee. The only exclusion to 
this guarantee is for negligent damage or damage to upholstery coverings. This 
guarantee does not require registration of the product as we can trace it from its 
serial number, however in the event of the serial number being removed, missing or 
unreadable then this may void the guarantee. These terms do not affect your 
statutory rights. 

In addition to the above Plinth Medical Ltd can offer both extended warranties and 
service contracts. For further information about either of these please contact: 

Customer Service 
Plinth Medical  
Barric Lane 
Occold 
Eye 
Suffolk 
IP23 7PX 
Tel: 01449 767887  
Mail: custome[email protected]

 

 
In the event of returning a product or part to us then please follow the instructions 
for cleaning under section 5 before enclosing it in suitable packaging and returning it 
to the above address. In addition please ensure there is a statement confirming that 
it has been decontaminated and what the fault is along with relevant contact details. 
 

Worldwide 

Please contact the distributor you purchased the chair from for service and support 
in your country. If you are unable to do so then please contact us in the UK and we 
will refer you to our local representative.  
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 503C

Page 1: ...Podiatry Chair Models 503C 503CD 503CT 503CDT USER MANUAL...

Page 2: ...Foot Section 7 Castor Operation 8 Armrest Operation 8 4 Accessories Operation 9 Paper Roll Holder 9 Battery Backup 9 Fold Down Cot Sides 10 Footswitch 10 5 Cleaning and Decontamination 11 6 Troublesh...

Page 3: ...ings are in a box with bold type and identify potential hazards procedures or conditions which could result in death injury or serious damage Cautions are in a box with plain type and identify conditi...

Page 4: ...he chair is used and whilst patients get on or off the chair Care should be taken to ensure patients do not trip over any part of the chair when getting off Adjustable Foot Fitted to the head end of t...

Page 5: ...le CAUTION When chair is not in use switch off power supply Lifting and Moving Should the chair need to be moved or lifted for example to remove it from its packaging then a minimum of two people are...

Page 6: ...ition the switch in a place where it is clear of the moving parts of the chair and where accidental operation is not possible Ensure that all electrical cables are clear of the moving parts of the cha...

Page 7: ...whilst adjusting and release the lever to lock in the desired position Manual Leg Sections For versions that do not have a motorised leg sections The operation is via a gas spring mechanism triggered...

Page 8: ...st be retracted before the chair is used and whilst patients get on or off Disconnect and coil electrical leads and switch away from the chair mechanism prior to moving the chair Armrest Operation The...

Page 9: ...fitting the tube over the bar Re fit in the reverse order Battery Backup Battery backup is a useful option in case of power shortages It allows at least one full cycle under battery power to enable t...

Page 10: ...lift up in the plastic block and then rotate a full 180 into the down position WARNING Ensure that the cot side is fully engaged in the plastic block whilst in use Footswitch An optional fitment foot...

Page 11: ...e mains supply to the chair and move it to a suitable cleaning area and lock the castors Step 1 Using warm water and soap on a damp cloth carefully wipe the chair over from top to bottom Take great ca...

Page 12: ...motor One motor will not work but others working 503CT 503CDT Lead from height motor control box not connected to slave motor Fault with switch Fault with control box Fault with motor Check and connec...

Page 13: ...y are present and tight but not over tight Upholstery bolts should all be checked each section has between 2 and 6 No M6 bolts they should all be present and tight Check gas struts if fitted and ensur...

Page 14: ...can offer both extended warranties and service contracts For further information about either of these please contact Customer Service Plinth Medical Barric Lane Occold Eye Suffolk IP23 7PX Tel 01449...

Page 15: ...Data 220 240v Motor s Linak LA31 x 1 Linak LA31 x 1 Linak LA31 x 2 Linak LA31 x 2 Control Box Linak CB09 Linak CB09 Linak CB09 Linak CB09 Current 1 5A 1 5A 1 5A 1 5A Power 360W 360W 360W 360W Mains P...

Page 16: ...me Date All Manual 01 Niall Dyer 13 06 2017 Plinth Medical Barric Lane Occold Eye Suffolk IP23 7PX ENGLAND Plinth Medical Ltd In association with Plinth 2000 are an ISO Audited company to ISO9001 2008...