Fold Down Cot Sides 

Fold down cot sides are available as an option and may only be used with the 

 

podiatry armrests removed. They are operated as follows:  

To raise the cot side

 from the 

down position; lift and rotate the 
cot side towards you through a 
full 180°. When upright push the 
cot side down into the plastic 
block until it is fully located. 

 

To lower the cot side

 from the 

upright position; lift up in the 
plastic block and then rotate a 
full 180° into the down position. 

 

WARNING 

Ensure that the cot side is fully engaged in the plastic block whilst in use. 

Footswitch 

An optional fitment footswitch may be specified for the chair and will look similar to 
the one pictured below. Note that the switch will vary depending on the model of 
chair and the number of motors fitted. The example below is for the 503CDT with 
motorised backrest (3 motor chair). 

 

 

 

 

 

 

Height (up/down) 

Tilt (up/down) 

Head rest (up/down) 

 

 

For chairs fitted with four motors the sequence shown above will remain with the 
fourth row of buttons operating the Foot rest.

 

Summary of Contents for 503C

Page 1: ...Podiatry Chair Models 503C 503CD 503CT 503CDT USER MANUAL...

Page 2: ...Foot Section 7 Castor Operation 8 Armrest Operation 8 4 Accessories Operation 9 Paper Roll Holder 9 Battery Backup 9 Fold Down Cot Sides 10 Footswitch 10 5 Cleaning and Decontamination 11 6 Troublesh...

Page 3: ...ings are in a box with bold type and identify potential hazards procedures or conditions which could result in death injury or serious damage Cautions are in a box with plain type and identify conditi...

Page 4: ...he chair is used and whilst patients get on or off the chair Care should be taken to ensure patients do not trip over any part of the chair when getting off Adjustable Foot Fitted to the head end of t...

Page 5: ...le CAUTION When chair is not in use switch off power supply Lifting and Moving Should the chair need to be moved or lifted for example to remove it from its packaging then a minimum of two people are...

Page 6: ...ition the switch in a place where it is clear of the moving parts of the chair and where accidental operation is not possible Ensure that all electrical cables are clear of the moving parts of the cha...

Page 7: ...whilst adjusting and release the lever to lock in the desired position Manual Leg Sections For versions that do not have a motorised leg sections The operation is via a gas spring mechanism triggered...

Page 8: ...st be retracted before the chair is used and whilst patients get on or off Disconnect and coil electrical leads and switch away from the chair mechanism prior to moving the chair Armrest Operation The...

Page 9: ...fitting the tube over the bar Re fit in the reverse order Battery Backup Battery backup is a useful option in case of power shortages It allows at least one full cycle under battery power to enable t...

Page 10: ...lift up in the plastic block and then rotate a full 180 into the down position WARNING Ensure that the cot side is fully engaged in the plastic block whilst in use Footswitch An optional fitment foot...

Page 11: ...e mains supply to the chair and move it to a suitable cleaning area and lock the castors Step 1 Using warm water and soap on a damp cloth carefully wipe the chair over from top to bottom Take great ca...

Page 12: ...motor One motor will not work but others working 503CT 503CDT Lead from height motor control box not connected to slave motor Fault with switch Fault with control box Fault with motor Check and connec...

Page 13: ...y are present and tight but not over tight Upholstery bolts should all be checked each section has between 2 and 6 No M6 bolts they should all be present and tight Check gas struts if fitted and ensur...

Page 14: ...can offer both extended warranties and service contracts For further information about either of these please contact Customer Service Plinth Medical Barric Lane Occold Eye Suffolk IP23 7PX Tel 01449...

Page 15: ...Data 220 240v Motor s Linak LA31 x 1 Linak LA31 x 1 Linak LA31 x 2 Linak LA31 x 2 Control Box Linak CB09 Linak CB09 Linak CB09 Linak CB09 Current 1 5A 1 5A 1 5A 1 5A Power 360W 360W 360W 360W Mains P...

Page 16: ...me Date All Manual 01 Niall Dyer 13 06 2017 Plinth Medical Barric Lane Occold Eye Suffolk IP23 7PX ENGLAND Plinth Medical Ltd In association with Plinth 2000 are an ISO Audited company to ISO9001 2008...

Reviews: