background image

 

 

The electrical connection must be made with shielded cable. 
Use cables with 0.75 mm

2

 for lengths up to 50 meters and cables with 1.5 mm

2

 for lengths up to 

100 meters. 
The  temperature  sensors  T2  (bottom  side  of  the  tank)  and  T3  (top  side  of  the  tank)  are  already 
placed in the pocket (under the thermoformed) and wired to the solar control unit. 
 
The electrical resistance (not supplied) must be installed on the sleeve on the front of the tank, so 
as to facilitate its insertion and its maintenance. 
 
The  sensor  pocket  for the  boiler  always  remains  (free)  on  the  back  of  the  tank,  the  other  is  the 
pocket for recirculation. 
 
If in doubt contact the technical department of Pleion. 
 
 

START UP 

 
Solar collectors 
Please see the assembly and start-up manual for the solar collectors model (X-RAY10, UNIKO, 
KSFG-25 and CSI). 

 
ECO COMPACT Tank 
The start up, made by the Service Center of competence, involves the following steps: 
- fill with water; 
- open the sleeves until the water comes out with a continuous stream; 
- adjust the safety valve; 
- Heat the tank only when it is completely full. 
Attention. The electrical resistance heater can be operated only when the tank is completely filled 
with water. 
After the first heating, tighten and check the tightness of all plumbing connections on tank. 
 
Solar control unit and pump 
The solar control unit has already been programmed at the factory for the proper functioning of 
electronic circulator and of the ECO COMPACT system. 
It  is  recommended  at  installers  and  end-user  to  don't  change  the  programming  of  solar  control 
unit, in order to prevent not correct operation of the system. 
For any changes to the settings of the unit please contact  the technical department of Pleion  or 
the Service Center of competence. 
Anyway ECO COMPACT system is delivered with the start-up manual of the solar control and of the 
pump in Italian and English language. 
 
 
 
 

Summary of Contents for ECO COMPACT 200

Page 1: ...1 ECO COMPACT SOLAR SYSTEM Assembly and start up manual Please contact Pleion S r l for any information not contained in this manual ...

Page 2: ...________________________________ 5 Plumbing instruction _____________________________________ 6 Electrical connections _____________________________________ 7 START UP _____________________________________ 8 Solar collectors _____________________________________ 8 ECO COMPACT Tank _____________________________________ 8 Solar control unit and pump _____________________________________ 8 WARRANTY C...

Page 3: ...ers against slipping falling over and sinking into the ground e g by using wider feet adjusting the ladder feet to the ground surface securing hook fixtures If no personal fall protection or fall arrest system is used there is a risk of falling from a great height which can lead to serious or fatal injury if no safety harness or equipment is used Only lean ladders against secure supporting surface...

Page 4: ...only by qualified personnel according to safety norms and regulations and as instructed in this document Only original components specific for this solar system must be used Before installation and start up please consult local norms laws and by laws Suitable restraining belts must be used during collector and tank transport Do not lift the collector and the tank by the screw thread connections Av...

Page 5: ...5 Technical Data Plumbing details ...

Page 6: ...nd or zinc Use brass fittings to tighten with metal weld copper with nickel silver staple or tighten fittings with high temperature seals loctite teflon high temperature Do not use hemp and paste commonly used hydraulic In both connections has been inserted a compass in order to increase the mechanical strength of the copper pipes in output from the solar station COLD SIDE HOT SIDE EXPANSION VESSE...

Page 7: ...0 20 cm The connection to the electric cabinet must be made by the installer The connection of the sensor T1 to the control unit has already been done at the factory The prolongation of the sensor T1 temperature sensor of the solar field comes out from the frontal cover in correspondence of the plumbing connections to solar collectors and ends with a power terminal POWER SUPPLY 220V 50Hz SOLAR SEN...

Page 8: ...up made by the Service Center of competence involves the following steps fill with water open the sleeves until the water comes out with a continuous stream adjust the safety valve Heat the tank only when it is completely full Attention The electrical resistance heater can be operated only when the tank is completely filled with water After the first heating tighten and check the tightness of all ...

Page 9: ... loading of the circuit will be necessary to have a solar charging station for solar installations REAR VIEW SOLAR STATION FRONT VIEW SOLAR STATION TAP LEFT ATTACK OF DISCHARGE OF SOLAR STATION TAP RIGHT ATTACK AGAINST THE SOLAR STATION ...

Page 10: ...gside the legal warranty Pleion offers a commercial warranty on defects in material or manufacturing of the products supplied with effect from the date of delivery for a period of 60 months for solar collectors 60 months for tanks 24 months for accessories and electrical or electronic components Warranty conditions and validity on Certificato di Garanzia Convenzionale supplied by Pleion s r l with...

Page 11: ...t to make any technical aesthetic and sales modification without no prior warning ING version Release 1 2 del 07 01 2013 Pleion Srl Via Venezia 11 37053 Cerea VR Tel 39 0442 320 295 Fax 39 0442 327 742 www pleion it info pleion it ...

Reviews: