CARE AND MAINTENANCE

 WARNING:

 Turn off heater and let cool before servicing. 

 

CAUTION:

 You must keep control areas, burner, and circulating air passageways of heater

  clean. Inspect these areas of heater before each use. Have heater inspected yearly by a

  qualified service person. Heater may need more frequent cleaning due to excessive lint

  from carpeting, bedding material, pet hair, etc.

 

WARNING

: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting  

  and property damage.

BURNER ORIFICE HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean 

burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet holes prior to 

each heating season. Blocked air holes will create soot. We recommend that you clean the unit every 

three months during operation and have heater inspected yearly by a qualified

service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. 

To clean these parts we recommend using compressed air no greater than 30 PSI. Your local

computer store, hardware store or home center may carry compressed air in a can. If using

compressed air in a can, please follow the directions on the can. If you don’t follow directions on the 

can, you could damage the pilot assembly.

BURNER FLAME PATTERN

Figure 29 shows a correct burner flame pattern. Figure 30 shows an incorrect burner flame pattern. 

The incorrect burner flame pattern shows sporadic, irregular flame tipping. The flame should not be 

dark or have an orange/reddish tinge.

Note: When using the heater the first time, the flame will be orange for approximately one hour until 

the log cures.

If burner flame pattern is incorrect, as shown in Figure 30

• turn heater off (see To Turn Off Gas to Appliance, page 23).

• see Troubleshooting, page 27.

2-6 inches

above logs

6-12 inches

above logs

Fig. 29 - Correct/Normal Flame Pattern 

with short flames 

Fig. 30 -Incorrect/Abnormal Flame  

Pattern with tall flames 

Summary of Contents for VFL2-EO18DT

Page 1: ...s air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air For Combustion and Ventilation section on page 9 of this manual This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with propane or natural gas This appl...

Page 2: ...er Specifications 2 Important Safety Information 3 Product Identification 5 Product Features 6 Preparing for Installation 7 Installation 10 Unpacking 15 Log Assembly 21 Operation 22 Care and Maintenance 25 Troubleshooting 27 Replacement Parts 30 Warranty 31 ITEM VFL2 SO18DT VFL2 EO18DT VFL2 WW18DT VFL2 SO24DT VFL2 EO24DT VFL2 WW24DT Input Rating 30 000 BTU Hr 30 000 BTU Hr Minimum Input Rating 15 ...

Page 3: ...this manual for reference It is your guide to operating this heater safely WARNING Due to high temperatures locate this appliance out of traffic and away from furniture and draperies Heater becomes very hot when operating Keep children and adults away from hot sur faces to avoid burns or clothing ignition Heater will remain hot for a time after shutoff Allow surfaces to cool before touching Carefu...

Page 4: ...his heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation page 9 If heater keeps shutting off see Troubleshooting page 27 11 Do not run heater where flammable liquids or vapors are used or stored under dusty conditions 12 Do not use this heater to cook food or burn paper or other ob...

Page 5: ...5 PRODUCT IDENTIFICATION Burner Tube Grate Thermostatic Control Valve Battery Ignitor Grate Cap LP ODS Pilot NG ODS Pilot Log Locator Spacer 4 ...

Page 6: ...assachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented propane or natural gas fired space heaters shall be prohibited in bedrooms and bathrooms In the State of Massachusetts the gas cock must be a T handle type The State of Massachusetts requires that a...

Page 7: ... a qualified service person We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Your local computer store hardware store or home center may carry compressed air in a can If using compressed air in a can please follow the directions on the can If you don t follow directions o...

Page 8: ...emove any large particles of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the orifice holder 6 In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4 Clean the pilot assembly also A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air inlet hole ab...

Page 9: ...ot connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad Electronic Push Button ignitor 7 Bad Battery 1 Replace electrode 2 Replace electrode 3 Replace ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Replace ignitor cable 6 Replace Electronic Push Button ignitor 7 Check Battery and replace if needed When ignitor but...

Page 10: ...an burner see Care and Mainte nance page 25 26 or contact cus tomer service Burner backfiring during combustion 1 Burner orifice is clogged or damaged 2 Burner is damaged 3 Gas regulator is damaged 1 Clean burner orifice see Care and Maintenance page 25 26 or contact customer service 2 Contact dealer or customer service 3 Replace gas regulator High yellow flame during burner combustion 1 Not enoug...

Page 11: ...fective Moisture conden sation noticed on windows 1 Not enough combustion ventilation air Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit 1 Residues from manufacturing process 1 Problem will stop after a few hours of operation 1 Turning control knob to high 5 position when burner is cold 2 Air in gas line 3 Air passageways on heater are blocked 4 ...

Page 12: ...1A H 0713B H 0713A 1 5 Log 5 1 H 0812 H 0812 H 0542 H 0542 1 6 Log 6 1 A 0668 A 0668 H 0374 H 0374 1 7 Log 7 1 A 0007 A 0007 2 Grate 1 GP287 01 GP288 01 GP287 01 GP288 01 3 Grate End Cap 1 GP287 02 GP287 02 GP287 02 GP287 02 4 ODS Pilot NG 1 GZ20 30B GZ20 30B GZ20 30B GZ20 30B 5 ODS Pilot LP 1 GZ20 29B GZ20 29B GZ20 29B GZ20 29B 6 Selector Knob 1 GZ20 17 GZ20 17 GZ20 17 GZ20 17 7 1 Regulator NG 5 ...

Reviews: