SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• for propane/LP units, propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.
Specifications
...................................................................................................................................2
Important Safety Information ............................................................................................................3
Product Identification
........................................................................................................................ 5
Product Features .............................................................................................................................. 6
Preparing for Installation................................................................................................................... 7
Installation ......................................................................................................................................10
Unpacking.......................................................................................................................................15
Log Assembly .................................................................................................................................21
Operation ........................................................................................................................................22
Care and Maintenance ................................................................................................................... 25
Troubleshooting ..............................................................................................................................27
Replacement Parts ......................................................................................................................... 30
Warranty .........................................................................................................................................31
ITEM
VFL2-SO18DT
VFL2-EO18DT
VFL2-WW18DT
VFL2-SO24DT
VFL2-EO24DT
VFL2-WW24DT
Input Rating
30,000 BTU/Hr
30,000 BTU/Hr
Minimum Input Rating
15,000 BTU/Hr
24,000 BTU/Hr
15,000 BTU/Hr
24,000 BTU/Hr
Gas Type
Natural
LP/Propane
Natural
LP/Propane
Ignition
Electronic Push
Button
Electronic Push
Button
Electronic Push
Button
Electronic Push But-
ton
Manifold Pressure
5 in. W.C.
10 in. W.C.
5 in. W.C.
10 in. W.C.
Inlet Gas Pressure *For purposes of input adjustment
Maximum
14 in. W.C.
14 in. W.C.
14 in. W.C.
14 in. W.C.
Minimum*
6 in. W.C.
11 in. W.C.
6 in. W.C.
11 in. W.C.