16
OPERATION INSTRUCTIONS
CONNECTING THE LP TANK
1. The knob on the LP tank must be closed. Make sure that the knob is turned
clockwise
to a full stop. The cylinder supply system must be arranged for vapor withdrawal.
2. Check that the control knob on the control unit is turned off.
3. Remove the protective cap from the LP tank valve and coupling nut.
4. Hold the regulator in one hand and insert the nipple into the valve outlet.
Be sure the nipple is centered in the valve outlet. The coupling nut
connects to the large outside threads on the valve outlet. Use care –
do not cross thread the connection.
5. Hand-tighten the coupling nut
clockwise until it comes to a full
stop. Firmly tighten by hand only. Do not use tools.
To Disconnect
: Fully close the tank valve by turning
clockwise.
Turn the coupling nut
counterclockwise until the regulator
assembly detaches.
WARNING
ALL INSTRUCTIONS AND SAFEGUARDS ON THIS PAGE MUST BE FOLLOWED TO
PREVENT FIRE, DAMAGE AND/OR INJURY.
ARNING
WARNING
In the connection process, make sure:
• the regulator inlet connector mates with the cylinder valve outlet properly, safely and firmly, and;
• the LP gas hose does not come in contact or remain in contact with the burner assembly.
CHECKING FOR LEAKS
After all connections are made, check all connections and fittings on the LP gas tank valve,
gas hose and regulator for leaks with a water and soap solution.
To prevent fire or explosion while testing for a leak:
• Always perform a leak test prior to lighting the fire pit.
• Do not smoke while testing for a leak.
• Always perform leak tests outdoors in a well-ventilated area.
• Do not use any source of flame while testing for leaks.
• Do not use the fire pit until any and all leaks are corrected.
• If you are unable to correct a leak, disconnect the propane supply and call a gas
appliance service dealer.
Before connection, be sure that there is no debris caught in the outlet of the gas cylinder, inlet of the
regulator valve or in the outlet of the burner and burner ports. Keep the propane cylinder valve closed
and disconnect the propane cylinder from the regulator valve when the fire pit is not in use.