DNS Local

Local DNS server translates URL’s and website names to their IP address.

DNS Address

Name or IP address of the DNS server that you want to connect to. Example: 
dns4.local or 10.1.1.50

DHCP

Dynamic Host Configuration Protocol is a standardized networking protocol 
used on Internet Protocol (IP) networks for dynamically distributing network 
configuration parameters, such as IP addresses for interfaces and services. 
With DHCP computers, request IP addresses and networking parameters 
automatically from a DHCP server, reducing the need for a network 
administrator or a user from having to configure these settings manually.

LLDP

Link Layer Discovery Protocol is a vendor-neutral link layer protocol in the 
Internet Protocol Suite used by network devices for advertising their identity, 
capabilities, and neighbors on an IEEE 802 local area network, principally 
wired Ethernet.

CDP

Cisco switch Discovery Protocol is a proprietary Data Link Layer protocol 
developed by Cisco Systems. It is used to share information about other 
Cisco equipment that are directly connected, such as the operating system 
version and IP address.

Batteries

 

y

The Net Prowler is powered by six AA alkaline batteries.

 

y

To replace batteries, open the back cover by unscrewing the single    

  screw with a Phillips head screwdriver.

 

y

Take out the old batteries and replace. Slide the new batteries in by    

  following the directional guidelines in the battery chamber.

 

y

Screw the back cover back on to the Net Prowler. Do not over tighten   

  the battery back cover.

Warning:

 Do not use carbon batteries. Do not mix new batteries 

with old batteries, due to the risk of battery leakage.

Cleaning

 

y

Use a clean, damp cloth to clean the Net Prowler. 

 

y

Before cleaning, disconnect all cables from the Net Prowler. Failing to  

  disconnect cables can damage the device and cause personal injury.

 

y

Do not use harsh cleaners, abrasives, or solvents.

Storage

 

y

When not in use, store the Net Prowler in a dry, protective case.

 

y

Batteries should be removed if the device is stored for a long time.

 

y

Do not expose the Net Prowler to high temperatures or humidity.  

  See the specifications section for temperature limits.

MAINTENANCE

Summary of Contents for Net Prowler TNP800

Page 1: ...to identify location on a hub switch router port y y Tests Ethernet cable configuration and verifies connectivity while conducting tests for opens shorts miswires split pairs and reverses y y Generat...

Page 2: ...Test 13 DHCP 13 Ping IPV4 IPV6 14 List 15 TCP UDP Test 16 Throughput 16 Cable Testing 17 Cable Testing Guidelines 17 Length Testing 17 Cable Testing with Remotes 17 How to Perform a Cable Test 18 Netw...

Page 3: ...wed on the unit Net Prowler PC Application Provides the ability to upload or download test results for saving viewing or printing Makes it easy to update Net Prowler firmware IPV4 and IPV6 support Net...

Page 4: ...twork Remotes 1 12 P N TRK220 ID Only Network Remotes 1 20 P N 4007 Hanging Pouch P N 4072 Durable Plastic Case P N 4008 Large Shoulder Bag P N TAK010 Hanging Strap with Carabineer Clip P N TAK020 Pro...

Page 5: ...conditions on the cable are detected and displayed on screen of your Net Prowler Cable Fault Description Miswire Cable s wire connection does not follow TIA568A TIA568B cabling standards Open Wire co...

Page 6: ...be used to measure coaxial cable y y TIA568A TIA568B Set the RJ45 wiring configuration to TIA568A or TIA568B wiring standard y y Pair Pin Set the RJ45 wiremap to measure by pair or pin y y Meters Feet...

Page 7: ...te If only temporary change is desired do not press the save button If the save button is not pressed the previous settings will be restored once the unit is powered off y y To restore factory default...

Page 8: ...oft key again y y Press the Test button to ping the IP address y y The Net Prowler will display the Response IP device name if available and response time in milliseconds List The Net Prowler will aut...

Page 9: ...motes Cable Tester Smart Remotes are used to verify connectivity at the opposite end of a cable and provide an ID To connect to a telephone cable use the included RJ12 no fault telephone patch cables...

Page 10: ...press the save icon Use the arrow buttons and the enter button to name the cable test file Press the Save icon to save the cable test file Network Power over Ethernet PoE Testing Power over Ethernet o...

Page 11: ...ts by sound Selection of this mode emits a cadence from the Net Prowler through the connected cable The tone is detected by a tone tracer probe Power on the Net Prowler Use the left or right arrow but...

Page 12: ...Delete All Tests To save the cable results to your computer Click on File on the tool bar at the top left Click on Save File A Save As dialogue will appear navigate to where you want to save the test...

Page 13: ...Important Notes The Net Prowler screen will remain dark until it has been reprogrammed If an error occurs during the download process follow the steps below y y Close the Net Prowler application y y...

Page 14: ...used to share information about other Cisco equipment that are directly connected such as the operating system version and IP address Batteries y y The Net Prowler is powered by six AA alkaline batte...

Page 15: ...Save Test Results Stores up to 256 Cable or network tests with user defined names Tone Generation Tone Frequencies 730 Hz and 1440 Hz Languages English French Spanish German Italian Battery Life For...

Page 16: ...tinum Tools for proper disposal options Returns Prior to returning any product to Platinum Tools you must first request a Return Merchandise Authorization Number by contacting the Customer Service Dep...

Reviews: