11
45-85A
105-160A
105-160A
105-160A
45-85A
105A
45A
125A
65A
160A
160A
105-125A
85A
45-85 A CONTACT CUT
105-160 A CONTACT CUT
105-160 A GOUGING
SK 165
487633
486021
425024
408642
408641
408640
482137
487634
486022
425024
408645
408644
408643
482137
487641
486022
425024
408633
408632
482137
FIG. F
Configuring the torch
for manual cutting
INTRODUCTION
These machines are supplied with the following standard torch-
es for manual cutting:
Torch
Length
SHARK 155
SK 165
6 m
Other lengths are available by request.
The torches are air cooled, and do not require special cooling.
The main nominal characteristics of the torches supplied, are
as follows.
SK 165
SK 165 = 6 m (standard)
(Other lengths are available by request)
160 A @ 60%
(10 min. 40°C)
DC
Cutting: 5,0-6,0 bar / 72-87 psi
Gouging: 3,5-4,0 bar / 50-58 psi
Gas flow @ 160 A: 420 l/min - 890 cfh
AIR
- Clean, dry, oil-free for ISO 8573-1 Class
1.2.2
N
2
- 99.95%
M
Without HF
IEC 60974-7
WORKING LIFESPAN OF CONSUMABLES
The following factors affect the frequency with which consum-
ables need to be replaced:
• Thickness of the metal cut.
• Average cut length.
• Air quality (presence of oil, moisture, or other pollutants).
• Execution of piercing of the metal or cutting from the edge.
• Correct piercing depth.
• Cutting done using mesh or solid material cutting mode. Cut-
ting done in mesh mode give rise to more wear of consum-
ables.
Under normal conditions, the nozzle wears out before the oth-
er consumables during cutting operations.
CONSUMABLES FOR MANUAL CUTTING
Figure F shows the consumables used for the plasma torches
supplied, complete with the CEA order codes.
These torches use shielded consumables and so the point of
the torch can be dragged over the metal to be cut.
Summary of Contents for SHARK 155