Copyright 2017 Planika Sp. z o.o.
www.planikafires.com
i1086#04
18.10.2017
3
INSTALLATION
ATTENTION! If you have purchased the original steel casing for the device, please follow the
instruction manual provided for the casing and skip the procedure described below.
−
Place the device in a housing that is closely connected to the construction of the building.
−
The elements of construction over the furnace must be made of non-flammable materials.
−
Recess, what will be done below the grate fireplace must be sealed.
−
Supply the housing with a loose cable min. 3 x 0,75 mm
2
, with power supply 230 V, 50 Hz, to connect
the device to the mains.
−
If there is going to be a cover over the furnace, it must be made of non-flammable materials and the
minimum distance from the furnace must be kept - not less than 35 cm/ 13 ¾ in.
−
It is not allowed to use a device before placing it into a prepared wall recess or other housing/cavity.
min 1000 mm
min 39
3
8
"
m
in
1
5
0
0
m
m
m
in
5
9
1 1
6
"
min 1000 mm
min 39
3
8
"
m
in
1
0
0
0
m
m
m
in
3
9
3
8
"
min. 50 mm
min. 1
15
16
"
min. 50 mm
min. 1
15
16
"
Due to fire safety, it is forbidden to place any flammable
materials within a 1 m (40 inches) radius from the fireplace.
Also, Planika does not recommend to place any heat
sensitive materials or devices within this radius as it can
significantly limit the materials properties and longevity.
Planika will not take any responsibility for the damage of any
materials or devices being installed above the fireplace.
Non-flammable
materials
Non-flammable
materials
Device cannot be installed
in a two-way open setting.